Advertisement

Quick Links

Contents
Preparing for installation ···································································· 1
Safety recommendations ············································································································· 1
Temperature and humidity requirements ························································································· 1
Installation accessories ··············································································································· 1
Installation tools ························································································································· 2
Installing the AP ··············································································· 3
Installation flowchart ··················································································································· 3
Pre-installation tasks··················································································································· 3
Determining the installation position ······························································································· 3
Mounting the AP ························································································································ 4
Mounting the AP on a wall ····································································································· 4
Mounting the AP on a ceiling ································································································· 7
Connecting IoT access units ········································································································· 8
Connecting the AP to the power source ·························································································· 9
Check before power-on ········································································································ 9
Connecting the PoE power supply ·························································································· 9
Connecting the local power supply ························································································ 10
Connecting a power injector ································································································ 11
Check after power-on ········································································································· 12
Connecting the AP to the network ································································································ 12
Appendix A Technical specifications ··················································· 13
Appendix B Ports and LEDs ····························································· 14
Ports ····································································································································· 14
LEDs ····································································································································· 15
i
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Advertisement

Table of Contents
loading

Summary of Contents for H3C WA5330

  • Page 1: Table Of Contents

    Contents Preparing for installation ···································································· 1   Safety recommendations ············································································································· 1   Temperature and humidity requirements ························································································· 1   Installation accessories ··············································································································· 1   Installation tools ························································································································· 2   Installing the AP ··············································································· 3   Installation flowchart ··················································································································· 3   Pre-installation tasks···················································································································...
  • Page 2: Preparing For Installation

    Preparing for installation Safety recommendations WARNING! Only qualified personnel can install and remove the AP and its accessories. You must read all safety instructions before installation and operation. To avoid possible bodily injury and equipment damage, read the following safety recommendations before installing the AP.
  • Page 3: Installation Tools

    Installation tools When installing the AP, you might need the following tools. Prepare the installation tools as required. Figure 2 Installation tools...
  • Page 4: Installing The Ap

    Installing the AP Installation flowchart Figure 3 Installation flowchart Start Pre-installation tasks Mount the AP on a wall Mount the AP on a ceiling Mount the AP Connect IoT access units Connect the AP to the power source Connect the AP to the network Pre-installation tasks Before installing the AP, perform the following tasks:...
  • Page 5: Mounting The Ap

    Mounting the AP The AP can be installed only indoors. You can mount the AP on a wall or a ceiling. The mounting bracket kit for the AP includes an AP bracket and a wall/ceiling bracket. To install the AP on a wall or ceiling, attach the AP bracket to the AP and the wall/ceiling bracket to the wall or ceiling.
  • Page 6 Figure 6 Attaching the AP bracket to the AP rear Mark the installation holes on the wall by using the wall/ceiling bracket, as shown in Figure Figure 7 Marking installation holes on the wall Drill holes with a diameter of 6 mm (0.24 in) and a depth of 30 mm (1.18 in) in the marked locations, as shown in Figure Figure 8 Drilling holes in the wall...
  • Page 7 Insert a screw anchor into each hole, and tap the screw anchor with a rubber hammer until it is all flush with the wall surface, as shown in Figure Figure 9 Hammering the anchor Align the installation holes in the wall/ceiling bracket with the anchors and insert screws through the installation holes into the screw anchors.
  • Page 8: Mounting The Ap On A Ceiling

    Mounting the AP on a ceiling CAUTION: The ceiling for installing the AP must be less than 18 mm (0.71 in) in thickness, and can bear a load of 5 kg (11.02 lb). If the ceiling is not strong enough, use boards to reinforce the ceiling as a best practice.
  • Page 9: Connecting Iot Access Units

    Figure 14 Attaching the AP to the wall/ceiling bracket Verify that the AP is securely installed to prevent it from falling off. Connecting IoT access units IMPORTANT: • To connect an access unit to the AP, you can use a straight-through or crossover Ethernet cable.
  • Page 10: Connecting The Ap To The Power Source

    Figure 15 Connecting IoT access units to the AP Connecting the AP to the power source You can supply power to the AP by using a local power source, a power injector, or through 802.3af/802.at PoE. To power the AP through PoE, use 802.at PoE as a best practice. When the AP has IoT access units connected to it, 802.3af PoE cannot satisfy the maximum power requirements of the AP.
  • Page 11: Connecting The Local Power Supply

    Figure 16 Connecting the PoE power supply Connecting the local power supply The power adapter must be ordered separately. Table 2 Power adapter specifications Item Specification Input 100 VAC to 240 VAC Output +54 VDC at 0.74 A You can power the AP by using an power adapter. Use the power adapter to connect the power port of the AP to the local power source.
  • Page 12: Connecting A Power Injector

    Connecting a power injector CAUTION: A power injector must be used together with an LPS-compliant adapter provided by H3C. The power injector must be ordered separately. Connect the power injector to the AP and a switch with Ethernet cable. Use the power adapter to connect the power port of the power injector to the local power source.
  • Page 13: Check After Power-On

    AP information State : I = Idle, J = Join, JA = JoinAck, IL = ImageLoad C = Config, DC = DataCheck, R = Run M = Master, B = Backup AP name APID State Model Serial ID WA5330 219801A20E8182012935...
  • Page 14: Appendix A Technical Specifications

    Appendix A Technical specifications Table 3 Technical specifications Item Specification Dimensions (H × W × D) (without 47.5 × 215 × 215 mm (1.87 × 8.46 × 8.46 in) the mounting bracket kit) Weight 728 g (1.60 lb) • 2.4 G: 6.33 dBi peak gain Antenna (built-in) •...
  • Page 15: Appendix B Ports And Leds

    Appendix B Ports and LEDs Ports The AP provides the following ports: • One console port • Two GE ports • One power port The AP also has a reset button and a security slot. The security slot is 7 × 3 mm (0.28 × 0.12 in) in size.
  • Page 16: Leds

    LEDs Table 5 LED description Status Description No power is present or the LED was turned off. The AP is initializing, or an initialization exception Steady on has occurred. Yellow Flashing at 1 Hz No radio cards have been detected. The Ethernet interfaces are down and no mesh links Flashing at 2 Hz are established.