Vibra Troubleshooting; Connectivity Module Troubleshooting; Introduction To Connectivity Module Troubleshooting - Nokia RM-701 Service Manual

Hide thumbs Also See for RM-701:
Table of Contents

Advertisement

RM-701
BB Troubleshooting and Manual Tuning Guide

Vibra troubleshooting

Troubleshooting flow

Connectivity module troubleshooting

Introduction to connectivity module troubleshooting

The BOB1.0M-b module supports WLAN, BT, FMRX and FMTX. From a troubleshooting point of view, WLAN and
FM TX are tested separately, but BT and FMRX are checked in parallel.
REFOUT_EXT1 single ended 38.4 MHz analog clock from Linko RF is provided to BOB1.0M-b. The clock request
for the reference clock in the BOB1.0M-b module is shared between WLAN and BT blocks. When either system
requires a clock, this signal will be active. The CLK_REQ is connected to ExtSysClkReq pin of RAPU. The SLEEPCLK
input of 32.768 KHz clock from EM ASIC is used for power management and for FM in low power mode. The
internal SMPS supplies the whole BOB1.0M-b solution from the phone battery supply, VBAT, apart from VIO
which is needed for interface signal reference levels.
The following figure shows a top level block diagram of the BOB1.0M-b module.
Page 3 – 44
COMPANY CONFIDENTIAL
Issue 1
Copyright © 2011 Nokia. All rights reserved.

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents