j) Capacitance measurement
1. Insert the black probe into the "COM" jack and the red probe into the "
2. Set the function switch to "
button until a capacitance unit appears on the screen.
3. Connect the probes to the two sides of the capacitor to be measured.
4. Read the reading indicated on the screen after it is stable (up to 30 s for large
capacitance).
Note
1. Before measuring, make sure to fully discharge the measured capacitors.
2. For low capacitance measurement, the relative value measurement method shall
be used to subtract the stray capacitance of the meter and probes, so as to make the
measurement results more accurate.
k) Frequency measurement
1. Insert the black and red probes into the "
2. Set the function switch to Hz.
3. Connect the probes to the two ends of the power or circuit to be measured.
4. Take readings on the screen,.
Note
The input voltage must be 1V rms ~ 20V rms. If the voltage is greater than 20V rms, the
reading accuracy may be outside the accuracy range.
l) Automatic power-off
03022
", and then press and hold the "function selection"
- 27 -