Firing in succession for a short period of time may cause the temperature inside this flash unit to rise. Changes in temperature are indicated by
the icons on the LCD display or by the beep sound (HVL-F60RM/HVL-F60RM2) according to the internal temperature value. While this flash
unit is in any warning state, flash charge-up is suspended.
HVL-F60RM/HVL-F60RM2
/
Indicates that the internal temperature is too high for this flash unit to fire (the flash unit is overheated). While [ON] is selected for [
BEEP] on the MENU screen, this state is also indicated by the beep sound. Turn off the power to the flash unit and leave it unused for
about 20 minutes.
Indicates that this flash unit is likely to be overheated. While the flash unit is in this state, flash charge-up is suspended for about 11
seconds. While [ON] is selected for [
Indicates that the internal temperature is extremely high. While the flash unit is in this state, flash charge-up is suspended for about 8
seconds. This warning state is not indicated by the beep sound.
HVL-F46RM
Indicates that the internal temperature is too high for this flash unit to fire (the flash unit is overheated). Turn off the power to the flash unit
and leave it unused for about 10 minutes.
BEEP] on the MENU screen, this state is also indicated by the beep sound.