(4) Remote controller display details setting
Make the settings for the remote-controller-related items as necessary.
Press the
button to save the changes.
[1] Clock display
[Button operation]
• Select "Clock" from the remote controller display details setting screen, and press the
(Change) to bring up the clock display setting screen.
• Use the
through
the Main display.
• Save the settings with the
• Administrator password is required. See (5) Administrator password. (The factory settings are
"Yes" (display) and "24 h" format. )
Clock display: Yes (Time is displayed on the Main display.)
No (Time is not displayed on the Main display.)
Display format: 24-hour format
12-hour format
AM/PM display (Effective when the display format is 12-hour): AM/PM before the time
Note: Time display format will also be reflected on the timer and schedule setting display. The
time is displayed as shown below.
12-hour format: AM12:00 ~ AM1:00 ~ PM12:00 ~ PM 1:00 ~ PM11:59
24-hour format:
[2] Temperature unit setting
[Button operation]
Move the cursor to the "Temperature" on the display details setting screen, and select the desired
temperature unit with the
• " ºC ": Temperature is displayed Centigrade. Temperature is displayed in 0.5- or 1-degree
increments, depending on the model of indoor units.
• " ºF ": Temperature is displayed Fahrenheit.
[3] Sensor value
[Button operation]
Move the cursor to "Sensor value" on the display details screen, and select the desired setting with
the
or
button. (The factory setting is "No.")
• Yes: Outdoor, return, and supply temperatures appear on the Main display.
• No: Outdoor, return, and supply temperatures do not appear on the Main display.
Note:
• Sensor value includes [Outdoor temperature], [Return temperature], [Supply temperature] or
[CO
concentration].
2
• The outdoor and return temperatures are detected by the thermometer of the product.
• PZ-70 series CO
2
• The supply temperature is calculated based on the standard heat-exchange efficiency.
• The values will differ from the actual outdoor, return, supply temperatures.
buttons to select "Yes" (display) or "No" (non-display) and its format for
button.
0:00 ~
1:00 ~
or
button. (The factory setting is Centigrade (ºC).)
sensor must be connected to display the [CO
AM/PM after the time
12:00 ~
13:00 ~
23:59
concentration].
2
Eng-12
Display details
Clock
Temperature
Sensor value
Select:
Cursor
Clock display
Clock
button
12h disp.
AM/PM disp.
Select:
Cursor
Display details
Clock
Temperature
Sensor value
Select:
Cursor
Display details
Clock
Temperature
Sensor value
Select:
Cursor
No 24h
Yes
/ No
Change
Yes
No
Cursor
No 24h
Yes
/ No
Change
No 24h
Yes
/ No
Change

Advertisement