6.2.5 Faculty tests
The faculty tests are selected by pressing the < / > button from the test mode menu. These tests test the
following faculties of this machine.
Test type
Sensor tests
Operation panel test
a) Sensor tests
The sensor test is selected by pressing the < / > button from the faculty test menu. In this test, you can
check the status of each sensor of this fax in item 1 on the display.
You can also check if sensors that use actuators and microswitches are operating correctly by moving
the actuator or microswitch.
NOTE
Download Free Service Manual And Resetter Printer at http://printer1.blogspot.com
Overview
Test whether the sensors are operating correctly.
Tests whether the button switches on the control panel are
operating correctly.
The sensor test does not permit a check on all sensors (e.g., pickup roller sensor). If the
pickup roller sensor is faulty, a message will appear indicating a recording paper jam.
SmartBase MPC200/imageCLASS MPC200
Chapter 4: Maintenance & Service
4-33