Risk of injury when opening and closing the hinges.
Keep your hands away from the hinges.
Adjust the appliance height on the remote control
1.
using the
button and the
If you have not carried out a reference movement,
the appliance automatically moves up and down as
far as it will go.
Open the hinges on the filter cover.
2.
25
Tighten the fastening screws on the hinges.
3.
Connect the cable on the appliance for the lighting.
4.
Close the cover on the cable duct.
5.
Remove the grease filters.
6.
To avoid causing damage, do not bend the grease
filters.
button.
Open the odour filter cartridge.
7.
Unpack the odour filter.
8.
Insert the odour filter.
9.
Insert the odour filter in the correct direction.
Fit the grease filters.
10.
To avoid causing damage, do not bend the grease
filters.
Swing the filter cover up and ensure that it engages.
11.
Removing the appliance
WARNING ‒ Risk of injury!
Components inside the appliance may have sharp
edges.
Wear protective gloves.
Cover the hob to prevent damage.
1.
Press the   button on the remote control.
2.
The appliance moves down as far as it will go.
Place a scissor lift table or another suitable device
3.
under the appliance.
Do not place the scissor lift table on the hob.
Move the scissor lift table up until the tension on the
4.
appliance cables is removed.
Notes
¡ Position the appliance on the scissor lift table so
that the appliance is on the frame.
¡ In order not to damage the grease filters, do not
set the appliance down on the grease filters.
Disconnect the appliance from the power supply.
5.
To protect against scratches, place the spacer on
6.
the appliance.