Cuppone Tiepolo KTP 435 Pre-Installation And Installation Manual

Cuppone Tiepolo KTP 435 Pre-Installation And Installation Manual

Hide thumbs Also See for Tiepolo KTP 435:

Advertisement

Quick Links

Tiepolo
HOOD
Pre-installation and installation manual
KTP 435
KTP 635
KTP 635L
KTP 935

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Tiepolo KTP 435 and is the answer not in the manual?

Questions and answers

Summary of Contents for Cuppone Tiepolo KTP 435

  • Page 1 Tiepolo HOOD Pre-installation and installation manual KTP 435 KTP 635 KTP 635L KTP 935...
  • Page 2: Table Of Contents

    InsTaLLaTIOn........................20 symbols used in the manual and on the labels applied to the machine ..20 CuPPOne 1963 Transport ..............................21 Cuppone f.lli s.r.l. Preliminary operations ........................21 Via sile, 36 serial number plate reading ......................21 Positioning and connection to the oven below............... 22 31057 silea (TV) - ITaLY Wiring diagrams: suction hood ....................
  • Page 3: Checks Before Purchasing

    CHeCKs BefOre PurCHasIng Before purchasing the hood and before installing it, check the When choosing the positioning room, take into account evacuation tube, 150 mm [Ø5,91 in.] in diameter (nOT supplied) following conditions, necessary for the correct installation, to move that the appliance must be easy for any operation and maintenance of the hood.
  • Page 4 Checks before purchasing Smoke evacuation (Owner’s inspection) The oven is fitted with an exhaust in the top to get rid of the steam from the cooking chamber. This steam, together with the one from the door during must be conveyed outside the work phases, through the hood.
  • Page 5: Hood Technical Data

    HOOD TeCHnICaL DaTa Units of Units of KTP435NT KTP435AS KTP635LNT KTP635LAS KTP 435 KTP 635L measurement measurement (neutral) (with extraction fan) (neutral) (with extraction fan) electrical supply electrical supply Volt aC 230 Volt aC 230 (50/60 Hz) (50/60 Hz) Maximum Maximum 0.13 0.13...
  • Page 6 Hood technical data a Oven supply input B Circuit breaker (only for american market) C equipotential D Hood supply input e Oven smoke exhaust f Hood fume inlet conduit g extraction fan...
  • Page 7 Hood technical data Fan technical data Characteristic curves - acoustic features [mmcda] [Pa] : flow in m : static pressure in mmcda and Pa - P: Incoming power in W - sfP: specific power factor in W/m /s (blue curves) Compliance data with IsO 5810 Sound pressure level* (dB(A)) Extraction...
  • Page 8: Ktp 435 Hood Technical Data | Hood + Single Oven

    KTP 435 hood technical data | hood + single oven 520mm 20,47in 520mm 20,47in 1040mm 40,94in 1330mm 52,36in 8,48in 215,50mm 1103mm 43,42in 35,67in 16,69in 906mm 424mm 8,31in 32,28in 211mm 820mm (19,88in) 505mm 2,95in 75mm...
  • Page 9: Ktp 435 Hood Technical Data | Hood + Double Oven

    KTP 435 hood technical data | hood + double oven 20,47in 520mm 20,47in 520mm 1040mm 40,94in 1330mm 52,36in 8,48in 1103mm 43,42in 215,50mm 35,67in 16,69in 906mm 424mm 8,31in 32,28in 211mm 820mm (19,88in) 505mm 2,95in 75mm Ed. 0221 - 70702510 REV04 Tiepolo hood - Pre-installation - Installation...
  • Page 10: Before The Installation, Read The Content Of This Manual Ktp 435 Hood Technical Data | Hood + Triple Oven

    KTP 435 hood technical data | hood + triple oven 520mm 20,47in 520mm 20,47in 1040mm 40,94in 1330mm 52,36in 215,50mm 8,48in 1103mm 43,42in 35,67in 16,69in 8,31in 32,28in 906mm 424mm 211mm 820mm (19,88in) 505mm 2,95in 75mm...
  • Page 11: Ktp 635 Hood Technical Data | Hood + Single Oven

    KTP 635 hood technical data | hood + single oven 20,47in 520mm 520mm 20,47in 1688mm 66,46in 215,50mm 8,48in 1040mm 40,94in 1103mm 43,42in 49,76in 16,69in 1264mm 424mm 8,31in 820mm 32,28in 211mm (34in) 865mm 2,95in 75mm Ed. 0221 - 70702510 REV04 Tiepolo hood - Pre-installation - Installation...
  • Page 12: Ktp 635 Hood Technical Data | Hood + Double Oven

    KTP 635 hood technical data | hood + double oven 66,46in 1040mm 40,94in 1688mm 520mm 20,47in 520mm 20,47in 1103mm 43,42in 215,50mm 8,48in 49,76in 16,69in 1264mm 424mm 8,31in 32,28in 211mm 820mm (34in) 865mm 2,95in 75mm...
  • Page 13: Ktp 635 Hood Technical Data | Hood + Triple Oven

    KTP 635 hood technical data | hood + triple oven 20,47in 20,47in 1688mm 66,46in 520mm 520mm 1040mm 40,94in 1103mm 43,42in 215,50mm 8,48in 8,31in 49,76in 16,69in 820mm 32,28in 211mm 1264mm 424mm (34in) 865mm 2,95in 75mm Ed. 0221 - 70702510 REV04 Tiepolo hood - Pre-installation - Installation...
  • Page 14: Ktp 635L Hood Technical Data | Hood + Single Oven

    KTP 635L hood technical data | hood + single oven 1330mm 52,36in 27,52in 27,52in 699mm 699mm 12,95in 1398mm 55,04in 43,42in 1103mm 329mm 35,67in 16,69in 906mm 424mm 12,78in 41,91in 324,50mm 1064,50mm (19,88in) 505mm 2,95in 75mm...
  • Page 15: Ktp 635L Hood Technical Data | Hood + Double Oven

    KTP 635L hood technical data | hood + double oven 1330mm 52,36in 55,04in 699mm 27,52in 699mm 27,52in 1398mm 12,95in 1103mm 43,42in 329mm 35,67in 16,69in 906mm 424mm 324,50mm 12,78in 1064,50mm 41,91in (19,88in) 505mm 2,95in 75mm Ed. 0221 - 70702510 REV04 Tiepolo hood - Pre-installation - Installation...
  • Page 16: Ktp 635L Hood Technical Data | Hood + Triple Oven

    KTP 635L hood technical data | hood + triple oven 1330mm 52,36in 55,04in 27,52in 27,52in 1398mm 1103mm 43,42in 699mm 699mm 12,95in 329mm 35,67in 16,69in 906mm 424mm 12,78in 41,91in 324,50mm 1064,50mm (19,88in) 505mm 2,95in 75mm...
  • Page 17: Ktp 935 Hood Technical Data | Hood + Single Oven

    KTP 935 hood technical data | hood + single oven 1688mm 66,46in 1398mm 55,04in 699mm 27,52in 699mm 27,52in 12,95in 1103mm 43,42in 329mm 49,76in 16,69in 1264mm 424mm 12,78in 41,91in 324,50mm 1064,50mm (34in) 865mm 2,95in 75mm Ed. 0221 - 70702510 REV04 Tiepolo hood - Pre-installation - Installation...
  • Page 18: Ktp 935 Hood Technical Data | Hood + Double Oven

    KTP 935 hood technical data | hood + double oven 1688mm 66,46in 699mm 27,52in 699mm 27,52in 12,95in 1398mm 55,04in 1103mm 43,42in 329mm 49,76in 16,69in 12,78in 41,91in 1264mm 424mm 324,50mm 1064,50mm (34in) 865mm 2,95in 75mm...
  • Page 19: Ktp 935 Hood Technical Data | Hood + Triple Oven

    KTP 935 hood technical data | hood + triple oven 1688mm 66,46in 699mm 27,52in 699mm 27,52in 1398mm 55,04in 1103mm 43,42in 12,95in 329mm 49,76in 16,69in 1264mm 424mm 12,78in 41,91in 324,50mm 1064,50mm (34in) 865mm 2,95in 75mm Ed. 0221 - 70702510 REV04 Tiepolo hood - Pre-installation - Installation...
  • Page 20: Installation

    InsTaLLaTIOn Safety instructions Symbols used in the manual and on work area during appliance assembly. • The serial plate provides important technical the labels applied to the machine • read this guide carefully before installing the information. This is vital in case of a request for appliance, and keep it with care in an accessible Indicates that caution is required when performing maintenance or repair of the equipment: please...
  • Page 21: Transport

    The serial number is on the back of the appliance. Model It provides important technical information that is vital in case CUPPONE F.lli S.r.l. of a request for maintenance or repair of the appliance: please Via Sile, 36 31057 Silea (TV) - ITALY P.
  • Page 22: 31057 Silea (Tv) - Italy Positioning And Connection To The Oven Below

    Installation 35 kg [77,1 lb] KTP435NT / 40 kg [88,1 lb] KTP435AS fig.7. 35 kg [77,1 lb] KTP635NT / 40 kg [88,1 lb] KTP635AS 43 kg [94,7 lb] KTP635LNT / 48 kg [105,8 lb] KTP635LAS 43 kg [94,7 lb] KTP935NT / 48 kg [105,8 lb] KTP935AS Positioning and connection to the fig.8.
  • Page 23 Installation Fig.9. fig.9. slightly move aside the side panel of the oven and disconnect the connection connector between the fan and the electrical panel of the oven. Fig.10. exclu- The electrical connection must be carried out sively by qualified personnel after reading the safety warnings at the beginning of the manual.
  • Page 24 Installation Inserting the filters Insert the filters as shown in the figure. fig.11.
  • Page 25: Wiring Diagrams: Suction Hood

    Wiring diagrams (eu version) Wiring diagrams (uL/Csa version) Suction hood yellow green 16/3 cable UL AWM supply from the oven Style 3644 CTRL CTRL Abbreviation Description Hood motor Abb. Description Motor start capacitor CTrL speed variation board Hood motor (not supplied) CTrL Control board Installed cable type...
  • Page 26: Smoke Extraction

    Installation Smoke extraction fig.12. The oven is fitted with an exhaust in the top to get rid of the steam from the cooking chamber. This steam, together with the one from the door during the must be conveyed outside work phases, through the hood.
  • Page 27: Pre-Testing And Final Inspection

    Installation Pre-testing and final inspection √ Positioning checks Reference chapter on page... Before delivery to the customer, the hood is checked and Preliminary operations Has the protective film been removed from the surfaces? on page tested in the Manufacturer's factories. Positioning and connection to the Is the equipment perfectly bound to the underlying oven? The “production process check sheet”...