Connection to the gas supply
The isolating manual shut-off valve connection point must be installed and accessible when the appliance is in
position. Gas inlet is located at the top rear right hand side, 50mm from the edge. This appliance is suitable for
connection with rigid pipe or flexible hose. For flexible hose connection, the flexible hose assembly must be
certified to AS/NZS 1869 class B or D, be of appropriate internal diameter for the total gas consumption, be kept as
short as possible (not exceeding 1200mm), must not be in contact with the floor or any hot or sharp surfaces. The
hose assembly must not be subject to strain, abrasion, kinking or deformation.
Gas connection
The gas inlet connection of the appliance has a "male thread." When making the connection, take care not to apply
stresses of any kind to the appliance.
A
Inlet pipe joint
B
Gasket
C
Stable union
Operation on Natural Gas
The supplied regulator must be fitted to the appliance inlet connection. Gas pressure must be adjusted to 1.0 kPa
when the auxiliary, semi rapid and rapid burners are set to high flame, the appliance test point is located on the
regulator.
Operation on Universal LPG
The supplied test point adaptor must be fitted to the appliance inlet connection. Gas pressure must be adjusted to
2.75 kPa, when the auxiliary, semi rapid and rapid burners are set to high flame, the appliance test point is located
on the test point adaptor.
When the installation is complete, always check that all the unions are absolutely tight using a soapy solution.
Never use a flame to make this check.