PHENOMENON

PROBLEM - SOLUTION

The air conditioner does not
work
The air conditioner can't run
after the immediate start-up
after it is shut down
Air conditioner stops running
after it starts up for a while
Cooling or Heating
performance is not satisfying
Indoor unit blows out odor
There is sound of running
water during operation
During turning on or turning
off the air conditioner there is
a cracking sound
Power failure
Wait until power recovers
Power plug may be loosed out from the socket
Place properly the plug in the socket
Power switch fuse may be blow
Replace the fuse
TIMER is on. The time for timing boot is yet to come
Wait or cancel TIMER setting
If the air conditioner is turned on immediately after it is turned off, the protective
delay switch will delay the operation for 3 to 5 minutes. This is self-compressor
protection procedure.
Setting temperature has been reached
It is a normal function phenomenon
May be at defrost state
It will automatically restore and run again after defrosting
TIMER is on
Wait or cancel TIMER setting
Excessive accumulation of dust on filter is blocking air inlet and outlet
Clean the air filters and remove the obstacles from air inlet and outlet
Voltage is too low
Wait until voltage resumes to normal levels
Air conditioner is working in AUTO mode
During AUTO mode, temperature cannot be changed. If you wish to change the
temperature change the mode of air conditioner
The angle of the louver blades is too small
Regulate the angle of the louver blades so the air flow can run freely
Poor Cooling or Heating may be caused by open doors and windows.
Close the doors and windows
Mode setting is incorrect. Temperature and fan speed settings are not appropriate
Re-select the mode and set the appropriate temperature and fan speed
Odor from the environment has been accumulated inside indoor unit
Clean the air filters and activate the self-clean function
During turning on or turning off the air conditioner, or when compressor stops and
starts again, the sound of running water may be heard from the indoor unit
This is the sound of refrigerant flow and it is normal
During turning on or turning off the air conditioner you may hear a cracking sound
from the indoor unit
Due to the temperature change, contraction / expansion is caused on the plastic
parts of the air conditioner. This is normal
9