6
Warning! Never apply power to the actuator until it has been securely bolted into place. The linear
actuator will tend to "unscrew" and will destroy the preset limit switch settings.
6.1) Loosen the cover screws and remove the actuator cover. The plastic strain relief might have been inverted
to protect it during shipping and hidden inside the actuator cover. Flip it around, reseat and snake the
actuator power wire through the strain relief.
WVW-VEN36" Linear Actuator
TOP Terminal 1
Controller Red to Actuator Red
BOT. Terminal 2
Controller Black to Actuator Black
The actuator motors are DC motors. The polarity of the DC power coming from the controller will dictate the
direction and movement of the actuator. Standard DC color codes are "relative" when applied to the actuator
motor connections.
DC input polarity during normal operation
Extension ( Tilt Array Up )
Retraction ( Lay Array Flat )
.

Power Connection to the Elevation Actuator

Red +
Red -
Black -
Black +