  • Page 1 DS-K3Y411X Series Flap Barrier Quick Start Guide...
  • Page 2 WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES,...
  • Page 3 During the use of device, personal data will be collected, stored and processed. To protect data, the development of Hikvision devices incorporates privacy by design principles. For example, for device with facial recognition features, biometrics data is stored in your device with encryption method;...
  • Page 4 DS-K3Y411X Series Flap Barrier Quick Start Guide Regulatory Information FCC Information Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
  • Page 5 DS-K3Y411X Series Flap Barrier Quick Start Guide under the EMC Directive 2014/30/EU, RE Directive 2014/53/EU,the RoHS Directive 2011/65/EU 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points.
  • Page 6 DS-K3Y411X Series Flap Barrier Quick Start Guide Safety Instruction These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. The precaution measure is divided into Dangers and Cautions: Dangers: Neglecting any of the warnings may cause serious injury or death. Cautions: Neglecting any of the cautions may cause injury or equipment damage.
  • Page 7 DS-K3Y411X Series Flap Barrier Quick Start Guide • Do not ingest battery, Chemical Burn Hazard. This product contains a coin/button cell battery. If the coin/button cell battery is swallowed, it can cause severe internal burns in just 2 hours and can lead to death. Keep new and used batteries away from children.
  • Page 8 DS-K3Y411X Series Flap Barrier Quick Start Guide • Please keep all wrappers after unpack them for future use. In case of any failure occurred, you need to return the device to the factory with the original wrapper. Transportation without the original wrapper may result in damage on the device and lead to additional costs.
  • Page 9 DS-K3Y411X Series Flap Barrier Quick Start Guide Available Models Product Name Model Description Example Flap Barrier DS-K3Y411X-L1 Left Pedestal 1 DS-K3Y411X-L1/Dp60 DS-K3Y411X-L1/Dp60- DS-K3Y411X-L2 Left Pedestal 2 DS-K3Y411X-L2/Dp60 DS-K3Y411X-L2/Dp60- DS-K3Y411X-M1 Middle Pedestal 1 DS-K3Y411X-M1/M- Dp60 DS-K3Y411X-M1/M- Dp60-S12 DS-K3Y411X-M2 Middle Pedestal 2 DS-K3Y411X-M2/M- Dp60 DS-K3Y411X-M2/M-...
  • Page 10 DS-K3Y411X Series Flap Barrier Quick Start Guide Scan the QR code to get User Manual of Flap Barrier. Note that mobile data charges may apply if Wi-Fi is unavailable.
  • Page 11: Table Of Contents

    DS-K3Y411X Series Flap Barrier Quick Start Guide Contents Chapter 1 Overview ........................1 1.1 Introduction ........................... 1 1.2 Main Features ........................1 Chapter 2 System Wiring ......................3 Chapter 3 Installation ......................... 6 3.1 Disassemble Pedestals ......................6 3.2 Install Pedestals ........................7 Chapter 4 General Wiring ......................
  • Page 12 DS-K3Y411X Series Flap Barrier Quick Start Guide 5.3 Switch Relay Output Mode (NO/NC) ..................38 5.3.1 Barrier Control Relay Output Mode ................38 5.3.2 Alarm Relay Output Mode (NO/NC) ................39 Chapter 6 Activation ......................... 42 6.1 Activate via SADP ......................... 42 6.2 Activate Device via Client Software ..................
  • Page 13: Chapter 1 Overview

    DS-K3Y411X Series Flap Barrier Quick Start Guide Chapter 1 Overview 1.1 Introduction The flap barrier with two barriers and 12 IR lights is designed to detect unauthorized entrance or exit. By adopting the flap barrier integratedly with the access control system, person should authenticate to pass through the lane via swiping IC or ID card, scanning QR code, etc.
  • Page 14 DS-K3Y411X Series Flap Barrier Quick Start Guide • Barrier is in open status when powered down; If the device is installed with supercapacitor, the barrier remains open when powered down • Fire alarm passing When the fire alarm is triggered, the barrier will be open automatically for emergency evacuation •...
  • Page 15: Chapter 2 System Wiring

    DS-K3Y411X Series Flap Barrier Quick Start Guide Chapter 2 System Wiring The preparation before installation and general wiring. Steps 1. Draw a central line on the installation surface of the left or right pedestal. 2. Draw other parallel lines for installing the other pedestals. Note The distance between the nearest two line is L+200 mm.
  • Page 16 DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 2-2 System Wiring Diagram (General Wiring) Note • The supplied interconnecting cable length is 3.75 m. If you need a longer one, you can buy a new accessory. • The suggested inner diameter of the low voltage conduit is larger than 30 mm. •...
  • Page 17 DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 2-3 Wire Face Recognition Terminal Note • The face recognition terminal installed on the left pedestal will gain power from the sub switch, which should connect to high voltage. • The suggested inner diameter of the low voltage conduit is larger than 30 mm. •...
  • Page 18: Chapter 3 Installation

    DS-K3Y411X Series Flap Barrier Quick Start Guide Chapter 3 Installation 3.1 Disassemble Pedestals Before installation, you should use the key to open the pedestals. View the pictures below to find the lock holes. Figure 3-1 Lock Holes Note Please check and avoid metal pieces dropped into the high and low voltage modules, which will cause short circuit.
  • Page 19: Install Pedestals

    DS-K3Y411X Series Flap Barrier Quick Start Guide 3.2 Install Pedestals Before You Start Prepare for the installation tools, check the device and the accessories, and clear the installation base. Steps Note • The device should be installed on the concrete surface or other non-flammable surfaces. •...
  • Page 20 DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 3-2 Dimension 1. Prepare for the installation tools, check the components, and prepare for the installation base. 2. Drill holes on the ground according to the installation holes on the pedestals and insert the expansion sleeves.
  • Page 21 DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 3-3 Installation Footprint 5. After installation, assemble the components and screws back to the pedestal in reverse order (except for protective sheets).
  • Page 22: Chapter 4 General Wiring

    DS-K3Y411X Series Flap Barrier Quick Start Guide Chapter 4 General Wiring Note • After maintenance, you should close the water-proof cover over the high/low voltage module. • When you should maintain or disassemble the high voltage modules, you should remove the entire high voltage modules and maintain it outside the turnstile.
  • Page 23: Wiring Electric Supply

    DS-K3Y411X Series Flap Barrier Quick Start Guide Note The reinstalled supercapacitor needs to be powered on for at least 3 minutes before it can work normally. The picture displayed below describes the IR adapter and the IR sending/receiving board and their corresponding number on the pedestal.
  • Page 24: Wire Interconnecting Cable

    DS-K3Y411X Series Flap Barrier Quick Start Guide Note • The cable bare part should be no more than 8 mm. It is suggested that you can immerse the bare part into the liquid tin. If possible, wear an insulation cap at the end of the bare cable. Make sure there’s no bare copper or cable after the wiring.
  • Page 25 DS-K3Y411X Series Flap Barrier Quick Start Guide Note The right/middle pedestal contains an interconnecting cable, including one network cable (3.75 m) and one 2-core cable. The picture displayed below describes the cable hole's position on the pedestals. Figure 4-3 Cable Hole of Interconnecting Cable Follow the instructions below to connect the interconnecting cable.
  • Page 26: Face Recognition Terminal Power Supply Wiring (Optional)

    DS-K3Y411X Series Flap Barrier Quick Start Guide 4.4 Face Recognition Terminal Power Supply Wiring (Optional) If connect to face recognition terminals, the face recognition terminals of right pedestal and middle pedestal (entrance) will power supplied by 12 V terminal on left side of the pedestal. The face recognition terminal of left pedestal and middle pedestal (exit) will power supplied by 12 V terminal of the power adaptor of the right pedestal.
  • Page 27 DS-K3Y411X Series Flap Barrier Quick Start Guide The reserved UART terminal positions in the turnstile and their corresponded UART No. are as follows: Note The diagram is for reference only. Figure 4-6 Interface and Corresponded UART No. The UART related terminals are on the access control board and BUS of the lane control board. You can switch between the RS-232 and the RS-485 communication modes via DIP switch.
  • Page 28 DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 4-7 UART No. Description Table 4-1 UART Related Position/Terminals/DIP Switch Introduction UART No. Related Terminals Terminal Position DIP Switch No. Function UART1 485A/232A BUS of Main Lane 1 to 3 ON: UART1 is RS- Control Board 232A Interface Note...
  • Page 29: Main Control Board Terminal Description

    DS-K3Y411X Series Flap Barrier Quick Start Guide UART No. Related Terminals Terminal Position DIP Switch No. Function 4 to 6 ON: UART3 is RS- Note 485C Interface External card 485C-/232C- Reserved reader is recommended to Reserved access. UART5 485E+/232E+ BUS of Sub Lane 1 to 3 ON: UART3 is RS- Control Board...
  • Page 30: Sub Control Board Terminal Description

    DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 4-8 Main Control Board Terminal 4.5.3 Sub Control Board Terminal Description The sub lane control board contains power input, BUS interface, interconnecting interface, supercapacitor interface, barrier position control board interface and motor drive interface. The picture displayed below is the sub control board diagram.
  • Page 31: Bus Terminal Description

    DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 4-9 Sub Control Board Terminal 4.5.4 BUS Terminal Description You can connect the lane controller light board, fan, TAMPER, lane control board, card reader, face recognition terminal, QR code scanner, etc. via the BUS terminal. Note Part of the wiring has been completed at the factory, please connect according to actual needs.
  • Page 32 DS-K3Y411X Series Flap Barrier Quick Start Guide Terminal Name Description UART 1 Red 12 V: connects 12 VDC power supply terminal Yellow 485A/232A+: card reader RS-485A+/RS-232A+ access Note terminal External card reader is Blue 485A/232A-: card reader RS-485A-/RS-232A- access recommended to access. terminal Black GND: grounding Table 4-3 BUS Terminal in Sub Lane Controller (Left Pedestal)
  • Page 33: Access Control Board Terminal Description

    DS-K3Y411X Series Flap Barrier Quick Start Guide Terminal Name Description Lane Controller Board Connect sub lane controller board Reserved IR Adaptor Connects IR adaptor UART 5 Red 12 V: connects 12 VDC power supply terminal Yellow 485E/232E+: card reader RS-485E+/RS-232E+ access Note terminal External card reader is...
  • Page 34 DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 4-10 Access Control Board Terminal Table 4-5 Access Control Board Terminal Description Access Control Board Terminal Description Power Output 1 +12 V 12 VDC Power Output Grounding RS-485 Interface RS-485 C+ Connect to Card Reader RS485+ •...
  • Page 35 DS-K3Y411X Series Flap Barrier Quick Start Guide Access Control Board Terminal Description in the main control board corresponds to the entrance card reader, and UART 5 in the main control board corresponds to the exit card reader. • If the user configured a guest card, the exit...
  • Page 36 DS-K3Y411X Series Flap Barrier Quick Start Guide Access Control Board Terminal Description card reader • This is the RS-485 interface, which cannot be switched by dialing. Power Output 2 5 VDC Power Output Grounding RS-232 Interface Grounding • This is the RS-232 RS-232 G- Connect to RS-232G-...
  • Page 37 DS-K3Y411X Series Flap Barrier Quick Start Guide Access Control Board Terminal Description through the embedded pipe and connects with the QR code on the left. Power Input +24 V 24 VDC Power Input Grounding Event Input Event Alarm Input 1 The event alarm input Grounding...
  • Page 38 DS-K3Y411X Series Flap Barrier Quick Start Guide Access Control Board Terminal Description for ordinary entrance, and D2 controls the door opening for ordinary exit. Door 2 Relay Output (Dry Contact) If necessary, the door lock relay can be used to control the third-party barrier switch.
  • Page 39: Access Control Board Uart Description

    DS-K3Y411X Series Flap Barrier Quick Start Guide 4.5.6 Access Control Board UART Description You can set the device mode, switch the communication mode of the corresponding UART, and initialize the device through the DIP on the access control board. The DIP switch of the access control board is shown in the figure below: Note The diagram is for reference only.
  • Page 40 DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 4-12 UART No. Description The corresponding functions of different DIP Switch are described as follows: Device Mode UART No. Function Binary Value DIP A 1 to 2: Work Normal Mode Mode Test Mode 3: Memory Mode Enable Memory Mode...
  • Page 41 DS-K3Y411X Series Flap Barrier Quick Start Guide Device Mode UART No. Function Binary Value Disable Memory Mode 4: Keyfob Paring Enable Keyfob Mode Paring Mode Disable Keyfob Paring Mode 5 to 8: Passing Controlled Bi- Mode direction Controlled Entrance and Prohibit Exit Controlled Entrance and Free...
  • Page 42 DS-K3Y411X Series Flap Barrier Quick Start Guide Device Mode UART No. Function Binary Value Prohibit Entrance and Free Exit DIP B 1 to 3 UART 5 ON: UART 5 is RS- 232E Interface 4 to 6 ON: UART 5 is RS- 485E Interface Reserved Default is OFF.
  • Page 43 DS-K3Y411X Series Flap Barrier Quick Start Guide The reserved UART terminal positions in the turnstile and their corresponded UART No. are as follows: Note The diagram is for reference only. Figure 4-13 Interface and Corresponded UART No.
  • Page 44: Rs-485 Wiring

    DS-K3Y411X Series Flap Barrier Quick Start Guide 4.5.7 RS-485 Wiring Note • The RS-485 interfaces are for connecting ID card reader, IC card reader, card reader, card recycler, text screen, and face recognition terminal. Take the wiring of RS-485 card reader as an example. •...
  • Page 45: Barrier Control Wiring

    DS-K3Y411X Series Flap Barrier Quick Start Guide 4.5.9 Barrier Control Wiring By default, the barrier has connected with the access control board. The lane control board can control the barrier status. If possible, the device can connect with a third party lane control board to control the third party barriers.
  • Page 46: Alarm Output Wiring

    DS-K3Y411X Series Flap Barrier Quick Start Guide Entering Wiring Exiting Wiring 4.5.10 Alarm Output Wiring Note For details about changing the relay output status via the jumper cap, see Alarm Relay Output Mode (NO/NC) .
  • Page 47: Chapter 5 Device Settings

    DS-K3Y411X Series Flap Barrier Quick Start Guide Chapter 5 Device Settings After installation and wiring completed, the turnstile will learn the open and closed position automatically. After the learning, the turnstile is in the normal mode. You can also set the turnstile to test mode, passing mode and memory mode, pair the keyfob, initialize the hardware, switching between RS-485 communication mode and RS-232 communication mode, and view relay output NO/NC diagram by setting the DIP switch on the access control board.
  • Page 48: Initialize Device

    DS-K3Y411X Series Flap Barrier Quick Start Guide By default, the keyfob is in one-to-one mode. The keyfob's DIP switch is towards 1 (OFF). The keyfob can control only one turnstile. One-to-Many Mode The keyfob's DIP switch is ON. In this mode, the keyfob can control multiple turnstiles. 1.
  • Page 49 DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 5-1 Initialization Jumper Cap 2. Disconnect the power and reboot the device. 3. When the beep stopped, set the No.8 switch to the OFF side, and reboot the turnstile to take effect. 4.
  • Page 50: Switch Relay Output Mode (No/Nc)

    DS-K3Y411X Series Flap Barrier Quick Start Guide 5.3 Switch Relay Output Mode (NO/NC) 5.3.1 Barrier Control Relay Output Mode The jumper cap of the barrier control relay on the access control board is as below: Figure 5-2 Jumper Cap Location (Barrier Control Relay Output Mode) The jumper cap position of barrier opening (NO) is as below:...
  • Page 51: Alarm Relay Output Mode (No/Nc)

    DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 5-3 Barrier Opening (NO) The jumper cap position of barrier closing (NC) is as below: Figure 5-4 Barrier Closing (NC) Note The default status is NC. 5.3.2 Alarm Relay Output Mode (NO/NC) The jumper cap of the alarm relay on the access control board is as below:...
  • Page 52 DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 5-5 Jumper Cap Location (Alarm Relay Output Mode) The jumper cap position of alarm opening (NO) is as below: Figure 5-6 Alarm Opening (NO) The jumper cap position of alarm closing (NC) is as below: Figure 5-7 Alarm Closing (NC)
  • Page 53 DS-K3Y411X Series Flap Barrier Quick Start Guide Note The default status is NO.
  • Page 54: Chapter 6 Activation

    • Get the SADP software from the supplied disk or the official website http:// www.hikvision.com/en/ , and install the SADP according to the prompts. • The device and the PC that runs the SADP tool should be within the same subnet.
  • Page 55: Activate Device Via Client Software

    DS-K3Y411X Series Flap Barrier Quick Start Guide Status of the device becomes Active after successful activation. 5. Modify IP address of the device. 1) Select the device. 2) Change the device IP address to the same subnet as your computer by either modifying the IP address manually or checking Enable DHCP.
  • Page 56 DS-K3Y411X Series Flap Barrier Quick Start Guide three kinds of following categories: upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you change your password regularly, especially in the high security system, changing the password monthly or weekly can better protect your product.
  • Page 57: Appendix A. Dip Switch Description

    DS-K3Y411X Series Flap Barrier Quick Start Guide Appendix A. DIP Switch Description The DIP switch is on the main lane control board. The left side to the right side is from the low bit to the high bit. When the switch is towards ON, it means the switch is enabled, otherwise, the switch is off. If you set the DIP switch like the figure displayed below, its binary value is 00001100, and its decimal value is 12.
  • Page 58: Appendix B. Event And Alarm Type

    DS-K3Y411X Series Flap Barrier Quick Start Guide Appendix B. Event and Alarm Type Event Alarm Type Tailgating Visual and Audible Reverse Passing Visual and Audible Force Accessing None Climb over Barrier Visual and Audible Overstay Visual and Audible Passing Timeout None Intrusion Visual and Audible...
  • Page 59: Appendix C. Table Of Audio Index Related Content

    DS-K3Y411X Series Flap Barrier Quick Start Guide Appendix C. Table of Audio Index Related Content Index Content Authenticated. Card No. does not exist. Card No. and fingerprint mismatch. Climbing over the barrier. Reverse passing. Passing timeout. Intrusion. Force accessing. Tailgating. No permissions.
  • Page 60: Appendix D. Error Code Description

    DS-K3Y411X Series Flap Barrier Quick Start Guide Appendix D. Error Code Description The swing barrier will display the error code on the seven-segment display if error occurred. Refer to the table below to find the description of each number. Error Reason Code Error Reason Code...
  • Page 61: Appendix E. Communication Matrix And Device Command

    Device Command Scan the following QR code to get the device common serial port commands. Note that the command list contains all commonly used serial ports commands for all Hikvision access control and video intercom devices. Figure E-2 Device Command...
  • Page 62 UD23418B-A...

Table of Contents