f Thermostat 1, 2, and solar heat panel are displayed as below when you set them with an indoor unit.
Thermostat 1 (Zone 1), Thermostat 2 (Zone 2), Solar heat panel (ON/OFF)
f Timer button: Whenever you press the button, the sensor value will be displayed in order.
Tw1(In)sensor
Tw2(Out1)sensor
TW3(Out2) sensor
Tank sensor
Indoor sensor
f While the sensor value is being displayed but you don't press the 'Timer' button for 5 seconds, the previous status will be
shown.
f For the sensor fault or absence of sensor installation, corresponding sensor temperature will be displayed as "Er".
f When you press the button that does not have a function,
will blink for 3 seconds.
f When pressing the Delete button one time, all the loads will be Off.
f When all the loads are OFF status, "Cancel" Key input will be ignored and
will blink for 3 seconds.
f When pressing the ESC button, you will exit to the general mode.