The housing should not be free standing but be
secured to the wall and/or adjacent fittings.
Provision for Ventilation
The appliance housing used must provide adequate
ventilation.
For built-in installation, a minimum ventilation space of
85 – 90mm 40mm must exist between the rear of the
appliance and the back of the housing or an adjacent wall.
If a tall housing is to be installed flush with the ceiling, a
20cm² ventilation cut-out must be provided at the top of the
housing.
Electrical Connection
This appliance must be installed by a qualified electrician
to comply with the relevant Institution of Engineering
and Technology (I.E.T.) regulations and also the local
electricity supply company requirements.
WARNING: THIS APPLIANCE MUST BE EARTHED
This appliance must be connected by a competent person,
using fixed wiring via a double pole switched fused spur
outlet, protected by a 13A fuse (Fig. 8.2).
We recommend that the appliance is connected by a
qualified electrician, who is a member of the N.I.C.E.I.C. and
who will comply with the I.E.T. and local regulations. The
wires in the mains lead are coloured in accordance with the
following code:
This appliance must not be connected to an ordinary
domestic power point.
The mains terminal is situated on the back of the oven
(Fig. 8.3).
GREEN AND YELLOW = EARTH
BLUE = NEUTRAL
BROWN = LIVE.
As the colours of the wires in the mains lead for the appliance
may not correspond with the coloured markings identifying
the terminals in your spur box, proceed as follows:
1.
The wire which is coloured green and yellow must be
connected to the terminal marked E (Earth) or coloured
Green.
2.
The wire which is coloured blue must be connected to
the terminal marked N (Neutral) or coloured Black.
3.
The wire which is coloured brown must be connected to
the terminal marked L (Live) or coloured Red.
Connect the cable to the correct terminals. Check that the
links are correctly fitted and that the terminal screws are tight.
Secure the mains cable using the cable clamp.
Ensure the cable route avoids the risk of trapping or touching
hot surfaces.
Check the appliance is electrically safe when you have finished.
INSTALLATION
N
L
14
DOUBLE POLE SWITCHED
FUSE SPUR OUTLET
13A
FUSE
ON
220V - 240V
1
2
3
R
L
PE
E
ArtNo.130-0006 - Electrical connections BI oven (60)
Fig. 8.2
Fig. 8.3
4
5