3 INTEGRATION INSTRUCTIONS
3.1
GENERAL
TWN4 Palon Compact LEGIC M may be installed in any host devices, as long as it is operated under the operational conditions stated
in the user manual and other technical documents (e.g. data sheet). TWN4 Palon Compact LEGIC M is equipped with two integrated
antennas. Thus, no antenna installation is required.
3.2
LIST OF APPLICABLE RULES
Refer to the approval certificates, grants and declarations of conformity issued for TWN4 Palon Compact LEGIC M, and to Chapter
"Compliance Statements" for a detailed list of the rules applicable to TWN4 Palon Compact LEGIC M.
3.3
SPECIFIC OPERATIONAL USE CONDITIONS
There are no specific operational use conditions for TWN4 Palon Compact LEGIC M other than the conditions mentioned in the user
manual and data sheet of TWN4 Palon Compact LEGIC M. The host manufacturer or integrator must ensure that these use conditions
comply with the use conditions of the host device. In addition, these use conditions must be stated in the user manual of the host
device.
3.4
LIMITED MODULE PROCEDURES
n/a
3.5
TRACE ANTENNA DESIGN
n/a
3.6
RF EXPOSURE CONSIDERATIONS
The module antenna(s) must be installed to meet the RF exposure compliance separation distance of 20 cm and any additional testing
and authorization process as required.
Refer to Chapter "Compliance Statements" for detailed information about the radio frequency exposure conditions applicable to
TWN4 Palon Compact LEGIC M.
These RF exposure conditions must be stated in the end-product manual(s) of the host product manufacturer.
3.7
ANTENNAS
TWN4 Palon Compact LEGIC M is equipped with the following antennas:
TWN4 Palon Compact LEGIC M
© 2021 ELATEC GmbH – TWN4 Palon Compact LEGIC M integration manual DocRev1 – 08/2021
HF antenna (13.56 MHz)
Dimensions: 39 x 42.5 mm / 1.54 x 1,67 inch
Number of turns: 3
LF antenna (125 kHz)
Dimensions: 27 x 27.5 mm / 1.06 x 1.08 inch
Number of turns: 179
Page 4 of 9