Figure 4-22. Module Spacer
PWRcell Battery modules and upgrade kits can be
obtained by contacting Generac Customer Service at 1-
888-436-3722
(1-888-GENERAC),
erac.com.
NOTE: Kits must be installed by a qualified individual.
Table 5 – Module Spacer Kit
Module Spacer Kit
Generac PWRcell Spacer Kit
To install module spacer:
1. See
Figure
4-23. Angle top of spacer (P) under
and behind bracket lip (Q).
Q
P
Figure 4-23. Installing Module Spacer (1 of 3)
2. See
Figure
4-24. Slide spacer up between brackets.
3. Push bottom of spacer in.
24
O
009933
or
www.gen-
Part Number
APKE00008
009934
1
2
Figure 4-24. Installing Module Spacer (2 of 3)
4. See
Figure
4-25. Secure spacer with two M4X8
SEMS screws and torque to 13 in-lb (1.47 Nm).
Figure 4-25. Installing Module Spacer (3 of 3)

Installing Retention Clips

See
Figure
4-26. All front battery modules must be
secured with retention clips (R).