Advertisement

November, 2016
JCM
TRAINING
®
OVERVIEW
DBV
Series
®
DBV-500 Banknote Validator
Phone (800) 683-7248
(702) 651-0000
Fax (702) 651-0214
E-mail support@jcmglobal.com
www.jcmglobal.com
®
© 2016 JCM American Corporation
Part No. 960-000187R_Rev. A
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DBV Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for JCM DBV Series

  • Page 1 November, 2016 TRAINING ® OVERVIEW Series ® DBV-500 Banknote Validator Phone (800) 683-7248 (702) 651-0000 Fax (702) 651-0214 E-mail support@jcmglobal.com www.jcmglobal.com ® © 2016 JCM American Corporation Part No. 960-000187R_Rev. A...
  • Page 2: Table Of Contents

    Software Download Procedures ........... 10 Performance Testing Procedures ......... 12 Performance Testing ................12 Available Tests Using the JCM Tool Suite Application ....... 12 Available Tests Using DIP Switch Block 1 .......... 14 Sensor Test .................... 15 Calibration ................16 Validation Sensor Calibration ..............
  • Page 3: Overview

    November, 2016 JCM® Training Overview DBV-500 Banknote Validator OVERVIEW This training course addresses the following JCM DBV-500 device versions: Table 1 DBV-500 Banknote Validator Versions Device Version Difference DBV-500 SU Upstack Unit DBV-500 SD Downstack Unit DBV-500 SD U Figure 1 illustrates the DBV-500 SD Banknote Validator Unit.
  • Page 4: Component Locations

    Cash Box Handle e) Cash Box Latches l) Frame Lock f) Unit Guide Open/Close Latches m) Plastic Latch g) USB Connector (for Maintenance) n) Metal Lock Figure 2 DBV-500 Component Names Part No. 960-000187R_Rev. A © 2016 JCM American Corporation...
  • Page 5: Dip Switch Settings

    VEND 4 ACCEPT VEND 5 INHIBIT VEND 5 ACCEPT VEND 6 INHIBIT VEND 6 ACCEPT TEST MODE OFF (OPERATING MODE) * See the Software Information Sheet (SIS) for proper Switch Settings. Lecture Notes Part No. 960-000187R_Rev. A © 2016 JCM American Corporation...
  • Page 6: Communication Settings

    OFF = ID-003 Mode ON = ID-0E4 Mode * For correct DIP Switch Block #2 Settings for other protocols, check the Software Information Sheet (SIS) for the specific protocol. Lecture Notes Part No. 960-000187R_Rev. A © 2016 JCM American Corporation...
  • Page 7: Setting The Led Bezel Default Color Setting

    5. Set DIP Switch Block #1 Switch #8 to OFF to save the Bezel LED color configuration. 6. Remove power from the DBV-500 Banknote Validator Unit. 7. Reset all DIP Switch settings on DIP Switch Block #1 and Block #2 to the original settings. Lecture Notes Part No. 960-000187R_Rev. A © 2016 JCM American Corporation...
  • Page 8: Sensor And Roller Cleaning Procedure

    Wipe Sensors (yellow areas) clean using a clean (slightly damp) lint-free Micro-fiber cloth. Centering Start Sensor Side Sensor Wipe Rollers (green areas) clean using a COB Sensor clean (slightly damp) lint-free Microfiber cloth. Exit Sensor Part No. 960-000187R_Rev. A © 2016 JCM American Corporation...
  • Page 9: Jcm Tool Suite Standard Edition

    3. Connect the Type-A connector to the USB Port on the PC. 4. Apply power to the DBV-500 Unit. 5. Open the JCM Tool Suite Application. When connected, the Device Information Fields will be filled in, as shown in Figure 4.
  • Page 10: Software Download Procedures

    Figure 5 , then click Figure 5 JCM Service Mode Drop-Down Menu The JCM Downloader Suite Edition display appears (Figure 6). “Browse” 2. To select the file to download, click (Figure 6 a). 3. From the folder that contains the DBV-500 download file, click the DBV-500 “Open”...
  • Page 11 CPU Circuit Board), set Forced Download Mode by setting DIP Switch Block #1 Switches #6, #7 and #8 ON. (The DIP Switches are located behind the Cash Box; remove the Cash Box to gain access). Lecture Notes Part No. 960-000187R_Rev. A © 2016 JCM American Corporation...
  • Page 12: Performance Testing Procedures

    JCM® Training Overview November, 2016 PERFORMANCE TESTING PROCEDURES ERFORMANCE ESTING Available Tests Using the JCM Tool Suite Application NOTE: Additional tests are available using DIP Switch Performance Testing Procedures. • Transport Motor Normal Rotation • Transport Motor Reverse Rotation • Stacking •...
  • Page 13 November, 2016 JCM® Training Overview DBV-500 Banknote Validator The Performance Test window appears as shown below. Figure 7 JCM Tool Suite Performance Test Window Lecture Notes Part No. 960-000187R_Rev. A © 2016 JCM American Corporation...
  • Page 14: Available Tests Using Dip Switch Block 1

    * DIP Switch Block #1 Switch 8 Setting: OFF to start Test, ON to stop Test. † Refer to Sensor Test and Table 7 on page 15 for Sensor and LED Conditions for the Sensor being tested. Part No. 960-000187R_Rev. A © 2016 JCM American Corporation...
  • Page 15: Sensor Test

    Home Position Box Detection When the Cash WHITE Sensor Box is installed * If multiple sensors are active, the status of the sensor with lowest priority is shown. Lecture Notes Part No. 960-000187R_Rev. A © 2016 JCM American Corporation...
  • Page 16: Calibration

    NOTE: The DBV-500 Unit’s Front Bezel LED will flash Green. 4. Connect the USB Type-A to Mini-B cable between your PC’s USB port and the USB port located on the DBV-500 Unit. “JCM Tool Suite Standard Edition” 5. Launch the software application.
  • Page 17 CPU Circuit Board needs to be changed; otherwise, click complete Calibration. Start 11.When the Sensor Calibration Screen appears (Figure 10), click the button (Figure 10 a) to save the Calibration Settings to EEPROM. Figure 10 DBV-500 Sensor Calibration Results Part No. 960-000187R_Rev. A © 2016 JCM American Corporation...
  • Page 18: White Level Test

    NOTE: The DBV-500 Unit’s Front Bezel LED will flash Green. 4. Connect the USB Type-A to Mini-B cable between your PC’s USB port and the USB port located on the DBV-500 Unit. 5. Launch the “JCM Tool Suite Standard Edition” software application. Service Mode Sensor Adjustment.
  • Page 19 Close 10.When the White Level Test is complete, click the (Figure 13 a) to close the White Level Test Screen and complete the process. Figure 13 DBV-500 White Level Test Complete Part No. 960-000187R_Rev. A © 2016 JCM American Corporation...
  • Page 20: Led Error Codes

    CPU Board Downloading White (3) White (6) Check file for DBV-500, Download proper software File Sensors detected abnormal condition, Clean White (3) White (8) I2C Access Sensors, check Stacker. Lecture Notes Part No. 960-000187R_Rev. A © 2016 JCM American Corporation...
  • Page 21: Operational Errors

    Red (3) Red (5) Transport Motor is Inoperative Motor Lock Centering Red (3) Red (6) Mechanism Centering Guide has not moved Contact your local JCM Representative if this error Red (3) Red (7) Reserved occurs. Fraud Red (3) Red (8)
  • Page 22: Banknote Reject Errors

    Sensors detected Banknote with abnormal timing Detection Banknote acceptance disabled by switch or Host Green (3) Green (5) Inhibit Setting settings Return Green (3) Green (6) Banknote return commanded by Host Command Lecture Notes Part No. 960-000187R_Rev. A © 2016 JCM American Corporation...
  • Page 23: Personal Notes And Comments

    DBV-500 Banknote Validator JCM® Training Overview November, 2016 PERSONAL NOTES AND COMMENTS Add relevant notes and comments regarding your installation here. Lecture Notes Part No. 960-000187R_Rev. A © 2016 JCM American Corporation...
  • Page 24: Dbv-500 Parts List

    "JCM American Corporation has been accredited as an Authorized Provider by the International Association for Continuing Education and Training (IACET)” JCM is a registered trademark of JCM American Corporation. All other product names mentioned herein may be registered trademarks or trademarks of their respective companies.

This manual is also suitable for: