SETTINGS
EN
1. Power
In the standby state, press the power button to turn on,
the operation indicator lights up and the default fan
speed is high, the LED shows ambient humidity. In the
power-on state, press the power button to turn off, the
running indicator light goes off and the compressor
stops immediately, and then the fan shut down after 30
seconds delay.
2. Mode
Auto mode - continuously drying mode-sleeping mode
cycle, press once to switch the mode from one to an-
other, the corresponding indicator lights up.
2.1. Auto mode:
when environmental humidity ≥ set humidity +3%, the
fan starts working and compressor starts working after 3
seconds. When environmental humidity ≤ set humidity
-3%, the compressor stops working and fan stops work-
ing after 30 seconds' delay.
Both fan speed and humidity can be adjusted under
auto mode.
2.2. Continuously drying mode
The machine continues to run, but the humidity can not
be adjusted.
2.3. Sleeping mode
Touch the sleep button, the button lights up and start
the sleep function. Long Press and hold the sleep button
3S to reset the filter
3. Timer
Press the timer button to set the 0-12 hour timing
function. The interval is 1 hour. Each time you press
this button, the value increased 1 hours and then the
corresponding timing value is displayed on the screen.
The setting value is "00" to cancel the timer function. The
indicator turns out. After the timer is set and completed,
the timer LED is on during the timing period. After the
timing is over, the timer LED turns off automatically.
In the running state, set the time to turn off the ma-
chine;
in the standby state, set the time to turn on the ma-
chine.
When press POWER will also exit the timer setting.
4. Speed
Only in automatic mode, touch this button to switch
between high and low fan speed, and the indicator light
is on.
4
Usage and Storage Instructions
5. Up
Press this button to set up humidity and timing time;
Humidity adjusting the order of 30% to 35% - 40% - 45%
- 50% - 55% - 60% - 65% - 70% - 75% - 80% - 30%;
Time set to 00, press this key, display 00 and blink, then
press this key again every time, from 01-02-03-.... -12
goes all the way up to +1
6. Down
Press this button to lower humidity setting and timing
time;
Humidity adjusting the order of 30% to 80% - 75% - 70%
- 65% - 60% - 55% - 50% - 45% - 40% - 35% - 30%;
Time set to 00, press this key, display 00 and blink, and
then press this key again every time, from 12-11-10-......
The value of -00 keeps repeating -1.
7. Child-lock
When the machine is turned on, press the button for
3 seconds to open/close the child lock function. When
the button is turned on, the indicator light of the child
lock is on. The indicator light of child lock is off; After the
child lock function is opened, the child lock function will
be cancelled automatically as long as the shutdown or
power failure occurs
DRAINAGE
There are two ways of removal collected water
produced by the unit.
A. Manual draining: Empty water tank by
manual.
B. Continuous draining: Use gravity to drain
condensate water by attaching a drain hose.

EMPTYING THE WATER TANK

The water tank built in unit will fill up and shut the unit
down once it is full. It will run again once you empty the
water tank and installed properly.
1. When the tank is full, The unit will make a buzzing
sound, and the "Water Full" light will turn on.
2. Press the POWER button to turn off the unit.
3. Pull on the water tank and simply slide out of the
body of the dehumidifier.
4. Empty the water into an area with a drain or outside.
5. Clean the inside of the tank as well as the outside.
6. Replace the empty tank back into the unit.
7. Press the POWER button to resume operating.
8. If the Water Full light does not extinguish, check that
the float is correctly in place.