2. Equipment Overview (continued)

2.2 Control Panel Description

A/M: Automatic or Manual starting mode
By pressing the A/M button, the user can change between Auto
(automatic) and MNL (manual) counting modes. In Auto, the default
setting, the equipment begins counting automatically when the bills are
placed on the hopper. In manual mode, the equipment will only begin
counting once the START key is pressed.
ADD: Adding function On / Off
This function allows the equipment to add up all the consecutive
operations made with this function ON.
SPEED: Change the speed between 1200-1500-1800 bill/min
Pressing the SPEED key repeatedly will display the three-speed options
available. Press "START" when the desired speed option appears.
** When the highest speed (1800 bill/min) is chosen, the MG function is not
available to be selected by the user**.
MG: Magnetic Verification On/Off (MG/UV model only)
Allows the equipment to analyze the magnetic features of each bill during
the counting process. The equipment will stop counting if a bill is
considered suspicious. The MG sensitivity can be adjusted by the user
from 1-9.
**When the MG function is active, the highest speed (1800 bills/min) is not
available to be selected by the user**.