Technical Specifications; General Specification - SATA 03015 User Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 22
Symbol description:
1)
Continuity test selected
2)
Diode test selected
3)
Auto range mode activated
4)
Relative value measurement mode activated
5)
Data hold mode is activated
6)
Negative sign
7)
communication
8)
DC
9
The battery used by the meter runs out of power and shall be replaced timely. Warning: To avoid false readings that can lead
to electric shock or personal injury, replace the batteries immediately when this symbol appears on the screen..
10) Units
mV、V
μA、mA、A
Ω、kΩ、MΩ
nF、μF
℃、℉
Hz、kHz、MHz
%
Technical specifications:
General Specification:
Specification of fuse for "
03015: 440mA, 1,000V, minimum breaking current 20,000 mA
03017: 630mA, 1,000V, minimum breaking current 20,000 mA Specification of fuse for "
20A, 1,000V, minimum breaking current 20,000A
Display of 03015: 3 3/4-digit LCD display with a maximum reading of 3999
Display of 03017: 3 5/6-digit LCD display with a maximum reading of 5999
Overrange indication: "
" appears on the LCD
Automatic negative polarity indication: "
Sampling rate: 2 to 3 times/sec (approximation)
Operating temperature: 0-40℃ , relative humidity: <75%
28
03015/03017
Voltageunits
Current unit
Resistance units
Capacitance units
Units of temperature
Frequency units
Duty cycle unit
" jack:
" appears on the LCD
中文
EN
DE
RU
KO
mV: Millivolt; V: Volt
1V=103mV
μA: microamp; mA: milliampere; A: Ampere
1A=103mA=106μA
Ω: Ohm; kΩ: kiloohm; MΩ megohm
1MΩ=103kΩ=106Ω=109mΩ
nF: nanofarad; μF: microfarad
1F=106μF=109nF=1012pF
° C: Celsius; ° F: Fahrenheit
f (℉)=32+1.8 x c (℃)
Hz: Hertz; kHz: kilohertz; MHz: Megahertz
1MHz=103kHz=106Hz
%: percent
" jack:
PT
JA
ES

Advertisement

Table of Contents
loading

This manual is also suitable for:

03017

Table of Contents