406-512 MHz
CSA40-67-DIN
ASSEMBLY INSTRUCTIONS
continued
STEP 3:
WITH THE ANTENNA ASSEMBLY LOCATED ON THE MOUNTING TUBE ATTACH THE REMAINING 2 LARGE
CLAMP PLATES AND TIGHTEN THE M12 NUTS CLAMPING THE ANTENNA ASSEMBLY TO THE MOUNTING
TUBE. TIGHTEN TO 55Nm (40 lbf.ft)
MOUNTING TUBE
(NOT INCLUDED)
ANTENNA MOUNTING HARDWARE HAS BEEN
DESIGNED TO ACCEPT MOUNTING TUBE
DIAMETERS IN THE RANGE OF 50-75mm (2-3")
MOUNTING TUBE LENGTH TO BE SIZED BY
INSTALLER TO SUIT INSTALLATION METHOD.
LARGE CLAMP PLATE
PLEASE NOTE MOUNTING POLE NOT SUPPLIED.