Operation
TDS RO
TDS DI
Press enter to display current TDS values
after the RO and after the DI.
Pressure
44psi
Temperature
Press enter again to display:
Pressure of mains water in PSI.
Temperature of water to hose (degrees C)
TDS RO
TDS DI
Press enter again to return to TDS values.
F
Start / Stop Filling
Increase a value
or go up to next
menu item
30
Total
1
Overall
Press enter again to display:
Total water used since last pre-filter change
and zeroing of counter.
Overall amount of water used since install.
Flow
18c
Press enter again to display:
Flow in litres per minute.
30
1
Decrease a value
Enter / Set a
or go down to
value or scroll to
next menu item
next display item
S3
Warning Messages
12.3kl
The S3 has a number of warning messages for when something goes wrong in the
200.5kl
system, these are designed to help with trouble shotting.
This message during a fill suggests that the
mains water has been disconnected.
2.4l/m
This message is displayed when the amount of
water that has flowed goes over the Total Flow
Threshold. Check the RO membrane.
This message is displayed when the system is
flushing and shortly after the system has
completed flushing.
This message is displayed when the system is
filling.
This message is displayed when the the TDS
exceeds the set limit.
WARNING
Water Discnnectd
This message indicates that the pressure
sensor has been disconnected or has
failed.
WARNING
Chk RO Membrane
The pressure has dropped below the value
set in Pressure Threshold, indicating a
blocked carbon or sediment filter.
System
Ignoring TDS
This message is displayed when the
system is flushing.
System
Filling
This message is displayed when the
system is full.
WARNING
High RO TDS
WARNING
High DI TDS
This message is displayed when the system
is paused by the TDS exceeding the limit
and the TDS Shutdown is 'On'.
S3
WARNING
Pressure Error
WARNING
Carbon Filter
System
Fill- Autoflush
System
Full
System
Filling paused
Need help?
Do you have a question about the S3 and is the answer not in the manual?
Questions and answers