4

OPERATION

4.1

GENERAL

Ensure that all heater interlock and safety devices are functional prior to
operation (refer to Section 2, Safety Requirements).
The IDH is designed to heat Deionized Water in either single pass (trim) or
recirculation applications up to 100°C. Figure 4-1 shows approximate flow
capacity versus temperature rise per fluid pass.
Minimum Flow Rate: 2 LPM (0.53 gpm)
Minimum Pressure: 0.10 MPa (15 psig)
WARNING: Element temperatures capable of heating beyond to 250°C.
Safety precautions should be taken (refer to Section 2, Safety Requirements).
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
2
3
4
4.2

LIQUID START-UP

Ensure that plumbing is secure.
Turn "On" the liquid supply.
Check for leaks in the system plumbing.
Allow the liquid to run through the system approximately 2 minutes prior to
energizing the heater.
PAGE 10
dT/Pass Water
5
6
7
8
9
Flow Rate (LPM)
Figure 4-1
MODEL IDH OPERATION / MAINTENANCE MANUAL
10
11
12
13
14
100% 6kW
100% 12kW
100% 18kW
80% 6kW
80% 12kW
80% 18kW
15
16
17
18