4. Replace second bushing lock nut.
5. Use 1 ¾" or 45 mm wrench, or adjustable wrench to firmly tighten the second bushing lock
nut.
Do not over tighten!
Step Five: Replace Sensing Plate
1. Place shaft of sensing plate into sensing head shaft socket.
2. Push inward and twist sensing plate until it cannot move further.
3. Line up channel at end of sensing plate shaft with roll pin and push shaft into place.
Siemens ILE-37 Sensing Head Diaphragm Replacement