Step Two: Secure Inner Diaphragm Ring
1. Line up the holes of the inner diaphragm ring with the holes of diaphragm and the holes on
the ILE-37 body.
2. Replace the four screws that connect the inner diaphragm ring to the ILE-37 body.
3. Use 5 mm Allen Key to firmly tighten the four screws.
Step Three: Replace LVDT Conditioner Card
1. Place metal spacers vertically over the screw holes.
2. Line up holes on LVDT conditioner card with the holes of the spacers.
Siemens ILE-37 Sensing Head Diaphragm Replacement
Application examples, 09/2020, AG050425
Planning/configuring
3.2 Part Two: Replace Diaphragm
13