PERFORMANCES
COP (*)
Heating time with heat pump (*)
Heating energy consumption (*)
Max. amount of
Delivered at 51°C
hot water in a
single intake V
40
Delivered at 62°C
(**)
Max. water temperature with heat
pump
Max. water temperature with
heating element
QPr (over 24h)
Power source
Voltage / max. power consumption
(*)
Frequency
Max. current consumption
(*) values obtained with air temperature of 7°C, 87% relative humidity and input water temperature of 15°C (in
conformity with the NF Cahier de Charge standard).
(**) Performance measured for heating of water between 15°C and 51°C with a temperature for the aspirated air of 15°C and 70%
relative humidity, in compliance with the cahier des charges of the NF Electricitè performance N°LCIE 103-15 mark relative to
independent storage water heaters.
(***) outside of the heat pump's interval of operation, heating of the water is ensured by the heating element..
Average value obtained on a significant number of products.
Heat pump water heater – GENERAL INFORMATION
Unit of
150 L
measurement
3,1
h:min
3:00
kWh
2,0
l
180
l
230
62 (55 factory default
°C
setting)
75 (65 factory default
°C
setting)
KWh
0,49
V / W
Hz
A
32
200 L
3,1
4:00
2,58
260
318
62 (55 factory default
setting)
75 (65 factory default
setting)
0,52
220-240 single-phase / 2500
50
10,8
300 L
3,1
6:24
4,28
426
549
62 (55 factory default
setting)
75 (65 factory default
setting)
0,63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nuos primo 100Nuos evo split 300