Download Print this page
Siamp Monaco Installation & Maintenance
Hide thumbs Also See for Monaco:

Advertisement

Quick Links

INTRASLIM PN
PNEUMATIC CONCEALED CISTERN DRY WALL
RESERVOIR PNEUMATIQUE ENCASTRE CLOISON SECHE
INSTALLATION & MAINTENANCE
N 50
N 100
N 50
90mm Slim
Silent
Anti
Water
Enjoy
Easy
Easy Access
Concealed Cistern
Function
Condensation
Saving
Instalation
Instalation
Maintenance

Advertisement

loading
Need help?

Need help?

Do you have a question about the Monaco and is the answer not in the manual?

Questions and answers

Summary of Contents for Siamp Monaco

  • Page 1 INTRASLIM PN PNEUMATIC CONCEALED CISTERN DRY WALL RESERVOIR PNEUMATIQUE ENCASTRE CLOISON SECHE INSTALLATION & MAINTENANCE N 50 N 100 N 50 90mm Slim Silent Anti Water Enjoy Easy Easy Access Concealed Cistern Function Condensation Saving Instalation Instalation Maintenance...
  • Page 2 2 / The internal stop valve should be regularly turned off and on to ensure that it remains serviceable. ✓  Siamp shall not be responsible or liable for improper installation of the product or of any cistern fitting damage caused by the use of cleaners containing chlorine...
  • Page 3 DIMENSIONS & CONFIGURATION A N 100 N 50 90 mm 90 mm 10~40 mm 10~40 mm IN STA L L AT IO N & MAI NTENANCE...
  • Page 4 DIMENSIONS & CONFIGURATION B N 100 N 50 I NSTA L L AT I O N & M A I NT E NA NC E...
  • Page 5 PREPARATION ➊ N 100 N 50 0~100 mm ➎ ➎ ➎ ➎ ➏ ➏ ➏ ➏ ➋ ➋ ➌ ➌ ➍ ➍ IN STA L L AT IO N & MAI NTENANCE...
  • Page 6 WALL FIXATION / FIXATION MURALE N 100 N 50 I NSTA L L AT I O N & M A I NT E NA NC E...
  • Page 7 WALL FIXATION / FIXATION MURALE N 100 N 50 IN STA L L AT IO N & MAI NTENANCE...
  • Page 8 WATER CONNECTION / CONNEXION EN EAU COMMAND PREPARATION / PREPARATION COMMANDE N 100 N 50 ➎ ➊ ➌ ➍ ➋ I NSTA L L AT I O N & M A I NT E NA NC E...
  • Page 9 WATER CONNECTION / CONNEXION EN EAU COMMAND PREPARATION / PREPARATION COMMANDE N 100 N 50 ➎ ➌ ➍ ➊ ➋ IN STA L L AT IO N & MAI NTENANCE...
  • Page 10 WATER CONNECTION / CONNEXION EN EAU ➍ N 100 N 50 ➊ ➋➎ ➌ ➍ I NSTA L L AT I O N & M A I N TE NA NC E...
  • Page 11 WATER CONNECTION / CONNEXION EN EAU ➍ N 100 N 50 ➊ ➋➎ ➌ ➍ IN STA L L AT IO N & MAI NTENANCE...
  • Page 12 CLADDING / HABILLAGE N 100 N 50 ➊ ➋ ➊ ➋ ➌ I NSTA L L AT I O N & M A I N TE NA NC E...
  • Page 13 CLADDING / HABILLAGE ➌ N 100 N 50 ➍ IN STA L L AT IO N & MAI NTENANCE...
  • Page 14 TOILET INSTALLATION / INSTALLATION DE LA CUVETTE  N 100 N 50 ➊ ➋ ➋ I NSTA L L AT I O N & M A I N TE NA NC E...
  • Page 15 TOILET INSTALLATION / INSTALLATION DE LA CUVETTE N 100 N 50 ➍ ➌ ➎ ➏ ➐ ➑ IN STA L L AT IO N & MAI NTENANCE...
  • Page 16 TOILET INSTALLATION / INSTALLATION DE LA CUVETTE N 100 N 50 ➒ ➒ I NSTA L L AT I O N & M A I N TE NA NC E...
  • Page 17 BUTTON AND COVER PLATE / BOUTON ET CACHE N 100 N 50 IN STA L L AT IO N & MAI NTENANCE...
  • Page 18 BUTTON AND COVER PLATE / BOUTON ET CACHE N 100 N 50 I NSTA L L AT I O N & M A I N TE NA NC E...
  • Page 19: Maintenance

    MAINTENANCE  En présence d’une eau d’une dureté > à 30°f, traiter périodiquement le réservoir contre le calcaire. N 100 N 50 ➌ ➋ ➊ ➊ ➋ IN STA L L AT IO N & MAI NTENANCE...
  • Page 20 MAINTENANCE ➍ N 100 N 50 ➎ ➏ ➐ ➑ n° 34 9513 07 I NSTA L L AT I O N & M A I N TE NA NC E...
  • Page 21 MAINTENANCE ➊ N 100 N 50 ➋ ➌ IN STA L L AT IO N & MAI NTENANCE...
  • Page 22 MAINTENANCE N 100 N 50 ➍ I NSTA L L AT I O N & M A I N TE NA NC E...
  • Page 23 MAINTENANCE ➎ N 100 N 50 ➏  Ref. : 34 5302 00 IN STA L L AT IO N & MAI NTENANCE...
  • Page 24 SK: Nevzťahuje sa na gumené časti. N 100 N 50 4, quai Antoine 1 - B.P. 219 - MC 98007 MONACO Cedex Tél. : +377 93 15 53 75 - Fax : +377 92 05 71 04 contact@siamp.com - www.siamp.com...