Toro Reelmaster 6500-D Service Manual page 151

Hide thumbs Also See for Reelmaster 6500-D:
Table of Contents

Advertisement

5
Reelmaster 6500-D/6700-D
1
Diagnostic ACE Display Functions
1. Overlay decal (English shown)
2
2. "Inputs Displayed" LED (Red)
3. "Outputs Displayed" LED (Green)
3
4. Toggle button
4
Figure 13
Using "Inputs Displayed" (Red Text)
1
1. LED lit if oil level is too high
2. LED lit if oil level is OK
2
a.
3. LED lit if oil level is too low
3
4. LED lit if slow leak detected
5. Target oil level - Cold oil & cutting units
4
raised
6. One or two LED's lit displaying
relative position of the Turfdefender's
b.
6
internal float
(any combination of 3, 3 or 4, or 4)
7
7. "Inputs Displayed" LED "ON" (Red)
Normal Operation:
a. "Oil Level OK" LED lit
b. 1 or 2 LED's lit on left column
Figure 14
Using "Outputs Displayed" (Green Text)
Normal Operation:
a. "Valve ON" LED lit steadily
b. "Self Diagnostic" LED lit steadily
c. "DATA LINE" LED lit steadily
d. "Alarm ON" LED lit temporarily
Problem Diagnosed:
The appropriate LED will blink to
identify the problem
Figure 15
Page 5 - 11