PowerSmoke
Read all safety instructions in the Safety Information section of the Engine Service Manual or
Engine Diagnostic Manual. Failure to comply may result in personal injury and / or death.
Safety Warnings:
• The maximum test pressure a PowerSmoke™ Adaptor may restrain can only be estimated
• Slippage of a PowerSmoke™ Adaptor is influenced by many factors including debris / residue in the Intake / Exhaust system,
coefficient of friction, internal pressure of the PowerSmoke™ Adaptor, and the accuracy of inflation instruments
• Generally, a PowerSmoke™ Adaptor properly inserted into an Intake / Exhaust system may begin slipping when test pressure exceeds
50% of the internal inflation pressure. Inflation pressure and back pressure limitations are subject to temperature / humidity change
• PowerSmoke™ Adaptor should NEVER be inflated over 1.6 times its outside diameter
• Debris, protrusions and residue in the Intake / Exhaust system could weaken and / or rupture the bladder of the PowerSmoke™
Adaptor. Bladder failures due to misuse or abuse are not covered by warranty. Redline Detection shall not be responsible for any
incidental or consequential damages
• PowerSmoke™ Adaptor must be mechanically anchored with the provided chain / cable to a secure location before use.
• PowerSmoke™ Adaptor slippage under test pressures may cause property damage or injury
• NEVER use inflation pressure with PowerSmoke™ Adaptor or a test pressure that is greater than the capacity of the weakest
component in the system under test
• NEVER use PowerSmoke™ Adaptor when its failure could cause injury or catastrophic damage
• Before use: Refer to PowerSmoke™ Adaptor Installation and Inflation procedures, back pressure limitations and tether restraint
installation instructions
1. Install PowerSmoke™ Adaptor fully into intake system ductwork or exhaust tubing. Make sure there are no obstructions or sharp
edges that might puncture bladder when inflated. PowerSmoke™ Adaptor must insert completely inside ducting / tubing
2. Install safety chain / cable to a secure location
3. Inflate PowerSmoke™ Adaptor to 30 PSI (2 BAR) maximum. If over inflated, pop off safety valve may release. If release occurs,
reinflate to 30 PSI (2 BAR)
4. Firmly tug on safety chain to insure PowerSmoke™ Adaptor is firmly installed and properly secure
5. Attach vapor hose for testing
SAFETY TIPS
• All diagnostic work should be performed with the engine off
• Do NOT use in EVAP system
• Ensure that the vehicle is secure and stable
• Exercise caution when connecting and disconnecting compressed shop air supply
• Do NOT leave a vehicle unattended while equipment is operating
• Always wear proper safety protection
• This safety guide is not intended to take the place of common sense and good judgment
Proper Installation
Removal of PowerSmoke™ Adaptor:
1. Remove vapor hose (or block-off coupler) at quick coupler to deflate tested system
2. ONLY AFTER system under test is fully depressurized, release internal pressure of PowerSmoke™
slowly by depressing Schrader valve
3. Detach safety chain / cable
4. Remove PowerSmoke™ Adaptor from ductwork, making sure not to rub across sharp edges
6