TROUBLESHOOTING

(also refer to the chapter on abnormal operating conditions)
PROBLEM
Dirty water
Excessive water consumption
Low water fl ow
from the hydromassage nozzles
No water fl ow
Pump and motor noisy
PROBABLE CAUSE
Filter clogged
Insuffi cient water treatment
High content of solid material in water
Improper maintenance
Leak on delivery line,
outlet line, connections
Excessive evaporation and/or
water overfl ow
Low water level
Filter clogged
Adjustable jets partially closed
Suction or drain pipes
partially clogged
Pump operates at a
speed that is too low
Pump gaskets worn or
damaged
Voltage too low
No current
Pump off
Motor not connected
Main switch turned off
Residual current operated circuit breaker
(RCCB) has tripped
Faulty pump or motor
Filters clogged
Water leakage on suction
43
SOLUTION
Clean or replace fi lter
See chapter on water treatment
See the instructions regarding
Maintenance
Repair the leak
Use the spa cover
Set a water temperature set point
lower
Fill until covering
the highest nozzles
Clean or replace fi lter
Open the jets
*
*
*
Contact an electrician or
the electric power utility
Turn main switches ON
Press the button
Check the motor connection
Turn on the switch
Reset the RCCB
*
Clean the fi lters
Find and repair leaks