Controlling Mode - TECHCON SYSTEMS TS555R User Manual

Smart controller for pneumatic valves
Table of Contents

Advertisement

Note: The digital values shown at "0" and "100" icons are for reference only.
The actual calibrated values will be different
7.
8.
The unit is now calibrated and ready to operate

5.1.3 Controlling Mode

The TS555R can be used as stand-alone controller or integrated to any
robot/automation system.
A. To use as Stand-Alone Controller:
B. To use as integrated controller to robot/automation
Stand-alone controlling
mode
Robot mode (integrate
to robotic system)
Touch the Reboot icon to save the settings and reboot the system
Wait until the system completes the rebooting sequence and the home
screen is displayed
Go to setup screen to check for controlling mode. If the icon "C" is
showing, then it is already set as stand-alone controlling mode. If the
icon "R" is showing, press this icon to change to "C"
Press icon "C" to change to "R"
Note: Users will experience inconsistent dispensing and intermittent
behaviors with their dispensing valves if attempting to run the TS550R
in controller mode when interfacing with the robot.