LED BaLLasT ByPass TUBE wiTh shaTTEr rEsisTanT COaTinG
nOTE: Keep your receipt and these instructions for proof of purchase
warninG: Shut off the power at the circuit breaker or fuse panel before removing the old fixture, ballast, or fluorescent tubes.
If you are unfamiliar with electrical installations, we recommend you contact a qualified electrician to do the installation.

INSTALLATION

1. Shut off power at the electrical panel before beginning the installation.
2. Remove existing fluorescent tubes and set aside to recycle in accordance with local requirements.
3. Remove and set aside the ballast cover, if needed.
4. Use the existing shunted sockets if they in good condition. If not, it is recommended that new shunted sockets (not included)
are installed.

ReTROfIT LumINAIRe wITh 1 LAmP

INSTANT START
PROGRAM START OR RAPID START
warninG:
• Risk of fire or electric shock. Installation of this LED Retrofit requires a person familiar with the construction and operation of the light fixture's/luminaire's electrical system and the
hazard involved. If not qualified, do not attempt installation. Contact a qualified electrician.
• Carefully read and understand the information given in this manual before beginning the assembly and installation. Failure to do so so could lead to electric shock, fire, or other
injuries which could be hazardous or even fatal.
• Install only in luminaires (light fixtures) that have the construction features and dimensions shown in the photographs and/or drawings included in these installation instructions.
• Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
• To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
CaUTiOn: Not for emergency lighting.
warninG: THIS RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING
JURISDICTION. • Installers should not disconnect existing wires from lampholder terminals to make new connections at lampholder terminals. Instead installers should cut existing
lampholder leads away from the lampholder and make new electrical connections to lampholder lead wires by employing applicable connectors. • THERE ARE LED TUBE, OPERATION
INSTRUCTION AND FIELD APPLIED LABEL IN THIS RETROFIT KIT. • This device is not intended for use with emergency exits. • Not suitable for use in vapor tight luminaires (light
fixtures).
The units covered by this report were intended to be retrofit surface mounted with a diffuser for this model number. Type IC and non-IC recessed mounted fluorescent luminaires use a
maximum of two lamps, the minimum lamp compartment dimensions are below:
nOTiCE: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio
or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna, increase the separation between the equipment and the receiver, connect the equipment into an outlet on a circuit different from that to which
the receiver is connected, and consult the dealer or an experienced radio/TV. Changes or modifications not expressly approved by the party responsible for compliance could void the
user's authority to operate the equipment.
See website for Warranty, Troubleshooting or Care and Cleaning details at www.ETiSSL.com.
La versión española está en el sitio
web www.ETiSSL.com.
UsE anD CarE GUiDE
Electronic
Ballast
47 3/4"
Fluorescent lamp
Electronic
Ballast
Fluorescent lamp
model

minimum Lamp Compartment Dimensions

Number
641011XX
Questions, problems, missing parts? Call ETiSSL Customer Service 8 a.m. - 5 p.m., CST, Monday - Friday
1-855-eTI-SSLI (1-855-384-7754) www.eTiSSL.com
1"
[Length x width x height] [in]
48.4 x 13.4 x 1.7
Part # T8BP-4-12-840-MV-DE-PET
T8BP-4-12-850-MV-DE-PET
Certification # 64101143

PACkAge CONTeNTS

Part
Description
A
LED Tube
B
UL Safety Sticker
LED lamp
LED lamp
maximum Lamp
Quantity
4
Ordering # 64101143
64101163
64101163
Quantity
1
1
A
B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 64101143 and is the answer not in the manual?

Questions and answers

Summary of Contents for ETI 64101143

  • Page 1 Ordering # 64101143 64101163 Part # T8BP-4-12-840-MV-DE-PET T8BP-4-12-850-MV-DE-PET Certification # 64101143 64101163 UsE anD CarE GUiDE LED BaLLasT ByPass TUBE wiTh shaTTEr rEsisTanT COaTinG PACkAge CONTeNTS nOTE: Keep your receipt and these instructions for proof of purchase warninG: Shut off the power at the circuit breaker or fuse panel before removing the old fixture, ballast, or fluorescent tubes.
  • Page 2 64101143 64101163 n° de pièce T8BP-4-12-840-MV-DE-PET T8BP-4-12-850-MV-DE-PET n° de certification 64101143 64101163 GUiDE D’UTiLisaTiOn ET D’EnTrETiEn TUBE DEL sans BaLLasT aVEC EnDUiT résisTanT à L’éCLaTEMEnT CONTeNu De L’emBALLAge rEMarQUE : Gardez votre facture ainsi que ces instructions comme preuves d’achat.

This manual is also suitable for:

64101163T8bp-4-12-840-mv-de-petT8bp-4-12-850-mv-de-pet

Table of Contents