Specifications - Honeywell Maxon OT FHR Manual

Table of Contents

Advertisement

Specifications

Capacities
®
OXY-THERM
FHR gas burners
Stated pressures are indicative. Actual pressures are a function of air humidity, altitude, type of fuel and gas quality.
®
OXY-THERM
FHR gas burners
Maximum capacity range
Turndown
Pressures required to
burner inlet for maximum
capacities
Typical oxygen to fuel
volumetric ratios
Approximate flame size
[1] sg (specific gravity) = relative density to air (density air = 0.0763 lb/ft
(See Application Engineering Data Sheet for OXY-THERM
®
OXY-THERM
FHR oil burners
®
OXY-THERM
FHR oil burners
Housing size
Oil nozzle
Maximum flow
gallons/hr
Fuel oil pressure @
psig
maximum (LFO)
Fuel oil pressure @
psig
maximum (HFO)
Turndown
Atomizing pressure
psig
(LFO)
Atomizing pressure
psig
(HFO)
Flame length range
feet 4-5.5
@ maximum
[1] Heavy fuel oils require heating to obtain proper viscosity (less than 100 SSU or 21 cs) for optimal atomization. Temperature of HFO should be
measured at burner inlet, not HFO storage tank or oil heater outlet.
(See Application Engineering Data Sheet for OXY-THERM
Burner fuel oil insert and oil piping near the fuel inlet should be purged with compressed air after shut down
to clear any remaining fuel oil. Failure to do so may cause plugging of oil atomizer and nozzle, and cause
poor or improper performance.
w w w . m a x o n c o r p . c o m
combustion systems for industry
Maxon reserves the right to alter specifications and data without prior notice.
Typical burner data
Fuel: natural gas at 60°F with 1000 Btu/ft
propane at 60°F with 2500 Btu/ft
MBtu/h
Oxygen (@ 50% staged)
Natural gas
psig
Propane
psig
To natural gas
To propane
Length
®
(LFO) = Light Fuel Oil; (HFO) = Heavy Fuel Oil [1]
Small (S)
Medium (M)
115
125
156
188
10.8
15.4
17.9
26.2
4-5.5
4.5-6
5-6.5
®
Dual fuel burners - OXY-THERM
3
(st) HHV - sg = 0.6 [1]
3
HHV - sg 1.57 [1]
®
OXY-THERM
Small (S)
Medium (M)
1.0 - 3.2
2.9 - 6.3
< 1.0 psig
< 1.0 psig
2.05 to 1
See graphs on page 3-18.4-9
3
(st) )
FHR burners for specific oxygen pressure information.)
Large (L)
218
250
281
312
35.3
50.9
57.4
66.4
75
95 0
3 to 1
60
80
5-6.5
8-10
10-12
10-12
FHR burners for specific oil pressure information.)
®
FHR
FHR gas burner size
Large (L)
Extra Large (XL)
6.0 - 13.1
10.0 - 24.0
3 to 1
< 1.0 psig
< 1.4 psig
1.2
2.5
5.1 to 1
Extra Large (XL)
328
344
391
422
82.7
94.6
122.2
132.2
11-13
12-14
13-15
14-16
3 - 18.4 - 5
E -
i
- 5/13
438
150.3
15-17

Advertisement

Table of Contents
loading

Table of Contents