1.5.4

Tool Status Lights

Handheld tools from STANLEY ASSEMBLY TECHNOLOGIES have three (green,
yellow, and red) status lights. The status light mirror or copy the status lights on
the controller or control panel.
Light
Status
Description
Green
Tightened to
The tightening cycle meets all of the
specified limits
specified parameters.
Yellow
Low torque or
The tightening cycle was rejected for not
angle
achieving either low torque or low angle.
Red
High torque or
The tightening cycle was rejected for
angle
exceeding either high torque or high angle.
All
Reverse
The next time the start trigger is engaged
lights
the tool will remove the fastener.
1.5.5

Setting Torque, Angle, and Other Operating Parameters

EXCESSIVE TORQUE CONDITION
To Avoid Injury:
• Only trained and qualified personnel should program controllers.
• Never set control limits above the maximum rating of the tool.
• Setting control limits above the maximum rating of the tool can cause
high reaction torque.
• Always test for proper tool operation after programming the controller.
The Alpha controller can be setup to change tightening Jobs or Tasks from the
tool's MFB.
Press, or hold, the MFB to change the operating program on the controller. See
section 1.4.2 for programming the MFB.
Press, or hold, the MFB to return the tool to the previous operating program.
QPM DC Electric Tools