Abilia Gewa Control 10 Manual

Abilia Gewa Control 10 Manual

Ir transmitter
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Manual
Gewa Control 10
SE: IR-sändare
GB: IR transmitter
NO: IR-sender
Art.no 425710
Rev H SE, GB, NO

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Gewa Control 10 and is the answer not in the manual?

Questions and answers

Summary of Contents for Abilia Gewa Control 10

  • Page 1 Manual Gewa Control 10 SE: IR-sändare GB: IR transmitter NO: IR-sender Art.no 425710 Rev H SE, GB, NO...
  • Page 2: Table Of Contents

    Innehållsförteckning/Content SE: Svensk Bruksanvisning Gewa Control 10 ..............5 Inledning ..........................5 Nyheter och förbättringar ....................5 Allmänt om Control 10 ......................5 Teckenförklaring ......................... 6 Sätta i batterier ........................6 Batterivarning ........................6 Inställningar ........................... 7 Nivåer i Control 10 ......................7 Låsa/låsa upp inställningslås ....................
  • Page 3 Safety and responsibility ...................... 36 Recycling Waste Electrical and Electronic Equipment ............36 Conformity with the Medical Devices Directive ..............36 Summary and Quick Guide Gewa Control 10 ..............37 NO: Norsk Brukerveiledning Gewa Control 10 ..............40 Innledning ..........................40 Nyheter og forbedringer ....................
  • Page 4 Tilbehør som følger med Control 10 ................. 52 Øvrig tilbehør til Control 10 ....................52 Sikkerhet og ansvar ......................53 Resirkulering av elektrisk avfall ..................53 Samsvar med det medisinske direktivet ................53 Sammenstilling Hurtigguide Gewa Control 10 ..............54...
  • Page 5: Se: Svensk Bruksanvisning Gewa Control 10

    SE: Svensk Bruksanvisning Gewa Control 10 Inledning Gewa Control 10 är en programmerbar IR-sändare som ersätter vanliga fjärrkontroller till TV, DVD, stereo mm. Control 10 har totalt 36 olika programmeringsplatser fördelade på fyra nivåer. Man trycker direkt på knapparna för att sända signaler, och byter nivå med Nivå- knappen.
  • Page 6: Teckenförklaring

    Bilden visar olika benämningar och funktioner som förekommer i texten. Fig 1 Indikeringslampa vid programmering Indikeringslampor som visar olika nivåer Nivå 1-4 Funktions-knappar 1-8 Kod-knapp Nivå-knapp Funktions-knapp Programmeringsknapp (reset) Teckenförklaring Följande symboler kommer att finnas med i texten: Programmeringsknapp Valfri knapp på Control 10 Valfri knapp på...
  • Page 7: Inställningar

    Inställningar Följande stycken beskriver hur man ställer in Control 10 för olika funktioner. Nivåer i Control 10 Control 10 har totalt fyra nivåer med 9 programmerbara knappar. De är vid leverans grundinställda med GewaLink-kanalerna 00-31 på nivå 1-4. Det är valfritt om man vill använda en, flera eller alla fyra nivåerna.
  • Page 8: Låsa/Låsa Upp Inställningslås

    Låsa/låsa upp inställningslås För att skydda kanaler/koder mot oavsiktlig radering när nya koder lärts in är det möjligt att låsa varje nivå för sig. Vid leverans är alla nivåer olåsta. Låst nivå indikeras med en ljudsignal vid inlärning. Gör enligt följande för att låsa/låsa upp nivåer: 1.
  • Page 9: Inlärning Av Ir-Kanaler Från En Annan Sändare

    Inlärning av IR-kanaler från en annan sändare Se till att batterierna i båda sändarna har god kapacitet. Placera inte sändarna i starkt ljus vid inlärning (t.ex. solljus). Lägg båda sändarna på ett bord med originalsändaren riktad mot den bakre gaveln på Control 10, se bild.
  • Page 10: Lägga In 4096-Kod

    Tips! Control 10 kan lära in koder från de flesta IR-sändare som finns på marknaden men det finns dock några enstaka undantag. Det kan vara enstaka funktioner eller alla funktionerna på en sändare. I dessa fall är det möjligt att pröva ett annat inspelningsläge. I punkt 2 gör man i stället enligt följande;...
  • Page 11: Kopiera Knapp

    Kopiera knapp Med Control 10 har man möjlighet att kopiera en knapps funktion till en annan knapp. OBS! Koden/kanalen ligger även kvar på ursprungsplatsen. 1. Välj nivå och tryck på den knapp vars kod skall kopieras. 2. Välj den nivå till vilken du vill kopiera koden. 3.
  • Page 12: Inställning Av Anslagsfördröjning

    Inställning av anslagsfördröjning Med Control 10 har man möjlighet att ställa anslagsfördröjningen av knappar, alltså den tid som en knapp måste hållas inne innan funktion erhålles. Anslagsfördröjningen går att ställa i 6 steg ( = ingen anslagsfördröjning och = maximal anslagsfördröjning (0,5 sek). Gör enligt följande: 1.
  • Page 13: Direktval Av Nivå

    Direktval av nivå Med Control 10 finns det möjlighet att skapa direktvalsknappar vilket innebär att det går att nå en nivå direkt genom att trycka på en utvald knapp. T ex om man befinner sig på nivå 1 och trycker på knapp 2 så kommer man direkt till nivå 2 eller genom att trycka på knapp 3 kommer man direkt till nivå...
  • Page 14: Kanalområde

    Kanalområde Med Control 10 har man möjlighet att ställa in olika kanalområden som sändaren ska arbeta inom. När inställningen görs försvinner eventuellt inlärda kanaler och en ny slumpvis kod läggs in på Kod-knappen Normalt behöver man inte byta kanalområde. Om flera GewaLink-sändare ska användas i samma område och man INTE vill styra samma utrustning kan det vara nödvändigt att använda olika kanalområden.
  • Page 15: Märkning

    Använd tillbehören Control Tool USB interface och Adapter 8-pol Mini Din/7-pol slits (säljs separat). Programvara laddas ned från Abilias hemsida. www.abilia.se. Se instruktioner på hemsidan. Rengöring Control 10 kan rengöras med en bomullstuss lätt fuktad med Alsolsprit, Klorhexidinsprit eller Etanol.
  • Page 16: Grundinställningar I Control 10

    Grundinställningar i Control 10 Vid leverans är Control 10 inställd med vissa grundinställningar enligt följande:  Anslagsfördröjning är inställd på värde 0  Återkoppling, ljudvolym är inställd på värde 3 (0 – 5)  Endast nivå 3 är öppen, övriga nivåer är stängda ...
  • Page 17: Tekniska Data

    Tekniska data Tekniska data ca 12 A Strömförbrukning i vila: Strömförbrukning vid sändning: ca 35 mA (GewaLink-kanal) Batterilivslängd: ca 2,5 år (100 sek sändning/dag med GewaLink- kanal) Programmeringsplatser: 36 st Manöverkraft knappar: < 160 gram Räckvidd: 20-30 m (GewaLink-kanaler) EMC-standard emission: EN 61000-6-4:2001, EN 60601-1-1-2:2001 ”...
  • Page 18: Säkerhet Och Ansvar

    Säkerhet och ansvar Abilia AB har utarbetat riskanalys för produkter i förhållande till SS-EN 14971 för Medicinsk utrustning. Produktens bruksanvisning och tekniska specifikation är utarbetad med tanke på säkerhetsvärderingarna som gjorts i detta dokument. Vid idrifttagning och dagligt användande av produkten är det alltid viktigt att tänka på...
  • Page 19: Sammanställning Snabbguide Gewa Control 10

    Sammanställning Snabbguide Gewa Control 10 Låsa upp/låsa inställningslås , --- 2sek , välj nivå med , tryck sedan önskat val eller = Låsa. = Låsa upp. Grundinställning: Upplåst Öppna/stänga nivå 2sek , välj nivå med , tryck sedan önskat val eller = Öppna.
  • Page 20 Inställning av anslagsfördröjning , välj inställning. = ingen anslagsfördröjning och = maximal anslagsfördröjning (0,5 sek). Grundinställning: Anslagsfördröjning = AV (0 sek). Lägga in Macro , skapa sekvens, välj nivå, , välj knapp Max 25 sek/tryck, 48 tryck Direktval av nivå Välj nivå...
  • Page 22: English Manual Gewa Control 10

    GB: English Manual Gewa Control 10 Introduction The Gewa Control 10 is a programmable IR transmitter, which replaces ordinary remote controls for TV, DVD, stereo etc. It has in all 36 different programming positions on four levels. Simply press the buttons to send signals, and change level by pressing the Level- button.
  • Page 23: Symbols

    This picture shows the various terms and functions which are described in the text. Fig 1 Indication lamp when Indication lights indicating programming (Ind) different levels: Level 1-4 Function-buttons 1-8 Code-button Level-button Function-button Programming button (reset) Symbols The following symbols appear in the text throughout this manual: Programming button Any button on your Control 10 Any button on another transmitter to be programmed...
  • Page 24: Settings

    Settings Below is described how to program your Control 10 for different setting options. Levels in Control 10 Your Control 10 has totally four levels with 9 programmable buttons. On delivery the buttons are factory-programmed with GewaLink channels 00-31 on level 1-4. You can freely use one, several or all four levels.
  • Page 25: Locking/Unlocking The Settings Lock

    Locking/Unlocking the Settings Lock In order to protect channels/codes from being erased by accident when new codes are programmed it is possible to lock each level separately. All levels are unlocked on delivery. A locked level is indicated by a beep when you try to program it.
  • Page 26: Recording Ir Channels From Another Transmitter

    Recording IR Channels from another Transmitter Make sure the batteries in both transmitters are fully charged. Do not use the transmitters in intense light (e.g., sunlight) when programming. Place the two transmitters on a table with the original transmitter directed towards the rear of your Control 10, see picture.
  • Page 27: Adding A 4096-Code

    Tip! Control 10 can record codes from most IR transmitters on the market with a few exceptions. You may have problems with a few or all of the functions for a certain IR transmitter. In these cases it is possible to try another recording method. Instead, do as follows in step 2;...
  • Page 28: Copying A Button

    Copying a button Using your Control 10, it is possible to copy a buttons’ function to another button. NOTE! The code/channel remains in its original place. 1. Choose level and press the button with the code to be copied. 2. Choose the level to which you want to copy the code. 3.
  • Page 29: Setting An Acceptance Delay

    Setting an acceptance delay Control 10 makes it possible to set an acceptance delay. By acceptance delay is meant the time a button has to be pressed before a result is reached. The acceptance delay can be set in 6 steps ( = no delay time and = maximum delay time (0.5 second).
  • Page 30: Direct Choice Of Level

    Direct Choice of Level Control 10 makes it possible to create quick buttons which means that you can reach a level by pressing a selected button. If you are at level 1 for instance and press button 2 you will directly reach level 2.
  • Page 31: Setting The Channel Range

    Setting the channel range Your Control 10 has the option to set different channel ranges for the transmitter to operate within. When the change of channel range is applied, programmed channels will disappear and a new random code is added on the Code-button Normally, the channel range does not need to be changed.
  • Page 32: Button Labelling

    The buttons on your Control 10 are marked with numbers as standard. The numbered label can be replaced with a personalised design. On Abilia’s website it is possible to create your own button labels using pre-designed templates with symbols and text.
  • Page 33: Backups And Reinstallation

    Use the accessories Control Tool USB Interface and Adapter 8-pole Mini Din/7-pole slits (sold separately). The software can be downloaded from Abilia’s website. www.abilia.org.uk. See instructions on the website. Cleaning Your Control 10 can be cleaned with a damp cotton wool pad with surgical spirit, Chlorhexidine or ethyl alcohol.
  • Page 34: Default Settings In Your Control 10

    Default settings in your Control 10 On delivery your Control 10 will be set with certain default settings as follows:  Acceptance delay is set to value 0  Feedback Beep Volume is set to value 3 (0 – 5) ...
  • Page 35: Technical Data

    Technical data Technical data Approx. 12 A Power consumption at rest: Power consumption at transmitting: Approx. 35 mA (GewaLink channel) Battery life: Approx. 2.5 years (100 seconds transmitting per day with GewaLink channel) Programming locations: 36 places Operating force buttons: <...
  • Page 36: Safety And Responsibility

    If you are not sure whether you have started using the product properly or set it up correctly, please contact your supplier. Abilia is not liable for any loss, damage or consequential loss resulting from any use, correct or otherwise, lack of follow-up, incorrect set-up, incorrect connection or similar misuse.
  • Page 37: Summary And Quick Guide Gewa Control 10

    Summary and Quick Guide Gewa Control 10 Locking/Unlocking the Settings Lock 2sec Press , choose level with then press your desired option then = Lock. = Unlock. Default setting: Unlocked Opening/Closing a Level 2sec Press , choose level with , then press the desired option , then = Open.
  • Page 38 Setting an acceptance delay , choose setting. = no delay time and = maximum delay time (0.5 second). Default setting: Acceptance delay = OFF (0 sec). Creating an automatic sequence (Macro) Press , create the sequence, choose level, , choose button Max 25 seconds per press, 48 presses Direct Choice of Level Create a quick button:...
  • Page 40: Norsk Brukerveiledning Gewa Control 10

    NO: Norsk Brukerveiledning Gewa Control 10 Innledning Gewa Control 10 er en programmerbar IR-sender, noe som betyr at den kan erstatte vanlige fjernkontroller til TV, video, stereo mm. Control 10 har totalt 36 forskjellige programmeringsplasser fordelt på fire nivåer. Man trykker direkte på knappene for at sende signaler, og bytter nivå...
  • Page 41: Tegnforklaring

    Bildet viser forskjellige betegnelser og funksjoner som forekommer i teksten. Fig 1 Indikeringslampe ved programmering (Ind) Indikeringslamper som viser ulike nivåer Nivå 1-4 Funksjons-knapper 1-8 Kode-knapp Nivå-knapp Funksjons-knapp Programmeringsknapp (reset) Tegnforklaring Følgende symboler finner du i teksten: Programmeringsknapp Valgfri knapp på Control 10 Valgfri knapp på...
  • Page 42: Innstillinger

    Innstillinger Følgende avsnitt beskriver hvordan en stiller inn Control 10’s ulike funksjoner. Nivåer i Control 10 Control 10 har totalt 4 nivåer med 9 programmerbare knapper. De er ved levering innstilt med GewaLink-kanaler 00-31 på nivå 1-4. Det er helt valgfritt om en vil bruke ett, flere eller alle 4 nivåene.
  • Page 43: Låse/Åpne Innstillingslås

    Låse/åpne innstillingslås For å beskytte kanaler/koder mot uforvarende sletting når nye koder læres inn, er det mulig å låse hvert nivå for seg. Ved levering er alle nivåer åpne. Låst nivå indikeres med et lydsignal ved innlæring. Gjør følgende for å låse/åpne nivåer: 1.
  • Page 44: Innlæring Av Ir-Kanaler Fra En Annen Sender

    Innlæring av IR-kanaler fra en annen sender Forsikre deg om at batteriene i begge senderne har full kapasitet. Plasser ikke senderne i direkte sollys under innlæring. Legg begge senderne på et bord med originalsenderen rettet mot den kortsiden som har kontakter på...
  • Page 45: Stille Inn 4096-Kode

    Viktig! Når kun ett nivå benyttes, vil Nivå-knappen automatisk inneholde kanalen på neste nivå’s første knapp, se Tabell 1. Det innebærer at det er fullt mulig å lære inn på Nivå- knappen når kun ett nivå er åpent. Tips! Control 10 kan lære inn koder fra de fleste IR-senderne som finnes på markedet, men det finnes noen få...
  • Page 46: Kopiere Knapp

    Stille inn 4096-kod , trykk --- eller 12 ggr. = Off-stilling. = On-stilling. Grunninnstilling: Tilfeldig kode Kopiere knapp Med Control 10 har en mulighet til å kopiere en signal som er innlært og grunnkanaler til andre plasser (knapper). Obs! Koden/kanalen blir liggende igjen på den opprinnelige plassen.
  • Page 47: Innstilling Av Knappeforsinkelse

    Innstilling av knappeforsinkelse Med Control 10 har en mulighet til å stille knappeforsinkelsen for aktivering av knapper, altså den tid som en knapp må holdes inne før den blir aktivert. Knappeforsinkelsen kan stilles inn på 6 forskjellige tider ( = ingen knappeforsinkelse og = maksimal knappeforsinkelse (0,5 sek.).
  • Page 48: Direktevalg Av Nivå

    Direktevalg av nivå Med Control 10 finnes det mulighet for å lage direktevalgsknapper som innebærer at det går an å nå et nivå direkte ved å trykke på en utvalgt knapp. Om en for eksempel befinner seg på nivå 1 og trykker på knapp 2, kommer en direkte til nivå 2, eller ved å trykke på knapp 3 kommer en direkte til nivå...
  • Page 49: Kanalområde

    Kanalområde Med Control 10 har en muligheten til å stille inn forskjellige kanalområder som senderen skal ha som arbeidsområde. Når innstillingene blir utført, forsvinner eventuelle innlærte signaler og en ny tilfeldig valgt kode legges inn på Kode-knappen Normalt trenger du ikke skifte kanalområde. Hvis flere GewaLink-sendere vil bli benyttet i det samme område og en IKKE ønsker å...
  • Page 50: Merking

    Bruk tilbehøren Control Tool USB interface og Adapter 8-pol Mini Din/7-pol slits (seljes separat). Programvare lastes ned fra Abilias hjemmeside. www.abilia.no. Se instruksjoner på hjemmesiden. Rengjøring Control 10 kan rengjøres med en bomullsdott fuktet med Alsolsprit, Klorhexidinsprit eller etanol.
  • Page 51: Grunninnstillinger I Control 10

    Grunninnstillinger i Control 10 Ved levering er Control 10 instillt med noen grunninnstillinger enlig følgende:  Knappeforsinkelse er stilled til 0  Tilbakemelding, lydvolum er stilled til 3 (0 – 5)  Kun nivå 3 er åpen, de andre nivåene lukket ...
  • Page 52: Tekniske Data

    Tekniske data Tekniske data ca 12 A Strømforbruk i hvile: Strømforbruk ved sending: ca 35 mA (GewaLink-kanal) Batterilevetid: ca 2,5 år (100 sek. sending/dag med GewaLink- kanal) Programmeringsplasser: 36 st Manøverkraft på knapper: < 160 g Rekkevidde: 20-30 m (GewaLink-kanaler) EMC-standard emisjon: EN 61000-6-4:2001, EN 60601-1-1-2:2001 ”...
  • Page 53: Sikkerhet Og Ansvar

    Dersom du er usikker på om du har innstilt eller satt produktet i drift på korrekt måte, anbefaler vi at du tar kontakt med din leverandør. Abilia AS er ikke ansvarlig for eventuelle skader, følgeskader eller tap som følge av bruk, feilbruk, manglende oppfølging, feil innstilling, feil oppkobling eller lignende. Abilia AS økonomiske ansvar er i alle tilfeller begrenset til verdien av selve produktet.
  • Page 54: Sammenstilling Hurtigguide Gewa Control 10

    Sammenstilling Hurtigguide Gewa Control 10 Låse/åpne innstillingslås 2sek , velg nivå med , trykk deretter ønsket valg eller = Låse. = Åpne. Grunninnstilling: Åpnet Åpne/lukke et nivå 2sek , velg nivå med , trykk deretter ønsket val eller = Åpne.
  • Page 55 Innstilling av knappeforsinkelse , velg innstilling. = ingen knappeforsinkelse og = maksimal knappeforsinkelse (0,5 sek.). Grunninnstilling: Knappeforsinkelse = AV (0 sek.). Lage automatisk sekvens (Makro) , lage sekvens, velg nivå, , velg knapp Maks 25 sek./trykk, 48 trykk Direktevalg av nivå , 1 , velg nivå...
  • Page 56 425710-1_Manual Gewa Control 10_SE GB NO_RevH.docx Feb 2017...

This manual is also suitable for:

425710

Table of Contents