Safety; Intended Use; Safety Regulations; Safety Assessment - Pilz PNOZ X9 Operating Manual

Safety relays
Hide thumbs Also See for PNOZ X9:
Table of Contents

Advertisement

PNOZ X9

Safety

Intended use

The safety relay PNOZ X9 provides a safety-related interruption of a safety circuit.
The safety relay meets the requirements of EN 60947-5-1, EN 60204-1 and VDE 0113‑1
and may be used in applications with
E-STOP pushbuttons
}
Safety gates
}
Light grids and safety switches with detection of shorts across contacts
}
The following is deemed improper use in particular
Any component, technical or electrical modification to the product,
}
Use of the product outside the areas described in this manual,
}
Use of the product outside the technical details (see
}

Safety regulations

Safety assessment

Before using a device it is necessary to perform a safety assessment in accordance with
the Machinery Directive.
Functional safety is guaranteed for the product as a single component. However, this does
not guarantee the functional safety of the overall plant/machine. In order to achieve the re-
quired safety level for the overall plant/machine, define the safety requirements for the
plant/machine and then define how these must be implemented from a technical and organ-
isational standpoint.
Operating Manual PNOZ X9
19526-EN-09
INFORMATION
This gives advice on applications and provides information on special fea-
tures.
NOTICE
EMC-compliant electrical installation
The product is designed for use in an industrial environment. The product
may cause interference if installed in other environments. If installed in other
environments, measures should be taken to comply with the applicable
standards and directives for the respective installation site with regard to in-
terference.
Technical details [
16]).