Pilz PNOZ X13 Operating Manual
Pilz PNOZ X13 Operating Manual

Pilz PNOZ X13 Operating Manual

Safety relays

Advertisement

PNOZ X13
}
Safety relays
Operating Manual-20187-EN-07

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PNOZ X13 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pilz PNOZ X13

  • Page 1 PNOZ X13 Safety relays Operating Manual-20187-EN-07...
  • Page 2 Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for the user's internal purposes. Suggestions and comments for improving this documenta- tion will be gratefully received.
  • Page 3: Table Of Contents

    Operation ..........................Status indicators ........................Faults – Interference ......................Dimensions in mm ......................... Technical details ........................Safety characteristic data ......................Supplementary data ......................Service life graph ........................Order reference ........................EC declaration of conformity ....................Operating Manual PNOZ X13 20187-EN-07...
  • Page 4: Introduction

    PNOZ X13 Introduction Validity of documentation This documentation is valid for the product PNOZ X13. It is valid until new documentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
  • Page 5: Safety

    This gives advice on applications and provides information on special fea- tures. Safety Intended use The safety relay PNOZ X13 provides a safety-related interruption of a safety circuit. The safety relay meets the requirements of EN 60947-5-1 and EN 60204-1 and may be used in applications with: E-STOP pushbuttons...
  • Page 6: Use Of Qualified Personnel

    Note for overvoltage category III: If voltages higher than low voltage (>50 VAC or >120 VDC) are present on the unit, connected control elements and sensors must have a rated insulation voltage of at least 250 V. Operating Manual PNOZ X13 20187-EN-07...
  • Page 7: Unit Features

    The correct opening and closing of the safety function relays is tested automatically in each on-off cycle. Block diagram/terminal configuration *Insulation between the non-marked area and the relay contacts: Basic insulation (over- voltage category III), Protective separation (overvoltage category II) Operating Manual PNOZ X13 20187-EN-07...
  • Page 8: Function Description

    PNOZ X13 Function Description The safety relay PNOZ X13 provides a safety-oriented interruption of a safety circuit. When supply voltage is supplied the "POWER" LED is lit. The unit is ready for operation when the start circuit S13-S14 is closed.
  • Page 9: Timing Diagram

    Auxiliary contact 61-62 should not be used for safety circuits! To prevent contact welding, a fuse should be connected before the output contacts (see Technical details [ 15]). Calculation of the max. cable length l in the input circuit: Operating Manual PNOZ X13 20187-EN-07...
  • Page 10 Important for detection of shorts across contacts: As this function for detecting shorts across contacts is not failsafe, it is tested by Pilz during the final control check. If there is a danger of exceeding the cable length, we recommend the following test once the unit is installed: 1.
  • Page 11: Preparing For Operation

    Safety gate with detection of shorts across contacts NOTICE With single-channel wiring the safety level of your machine/plant may be lower than the safety level of the unit (see Safety characteristic data [ 19]). Operating Manual PNOZ X13 | 11 20187-EN-07...
  • Page 12 S3: Reset button : Switch operated : Gate open : Gate closed INFORMATION With automatic start, S33 and S34 must not be linked; with monitored start, S13 and S14 must not be linked. Operating Manual PNOZ X13 | 12 20187-EN-07...
  • Page 13: Operation

    LEDs indicate the status and errors during operation: LED on POWER Supply voltage is present. START Start circuit is closed. CH.1 Safety contacts of channel 1 and 3 are closed. CH.2 Safety contacts of channel 2 and 4 are closed. Operating Manual PNOZ X13 | 13 20187-EN-07...
  • Page 14: Faults - Interference

    Contact malfunctions: If the contacts have welded, reactivation will not be possible after the input circuit has opened. LED "POWER" does not light: Short circuit or no supply voltage. Dimensions in mm 75 (2.95") 87 (3.42") (1.77") Operating Manual PNOZ X13 | 14 20187-EN-07...
  • Page 15: Technical Details

    Utilisation category of safety contacts AC1 at 240 V Min. current 0,01 A Max. current Max. power 2000 VA DC1 at 24 V Min. current 0,01 A Max. current Max. power 200 W Operating Manual PNOZ X13 | 15 20187-EN-07...
  • Page 16 External contact fuse protection, auxiliary contacts Max. melting integral 240 A²s Blow-out fuse, quick 10 A Blow-out fuse, slow Blow-out fuse, gG 10 A Circuit breaker 24 V AC/DC, characteristic B/C Contact material AgSnO2 + 0,2 µm Au Operating Manual PNOZ X13 | 16 20187-EN-07...
  • Page 17 EN 60947-5-1, EN 61000-6-2, EN 61326-3-1 Vibration In accordance with the standard EN 60068-2-6 Frequency 10 - 55 Hz Amplitude 0,35 mm Airgap creepage In accordance with the standard EN 60947-1 Overvoltage category III / II Pollution degree Operating Manual PNOZ X13 | 17 20187-EN-07...
  • Page 18 Torque setting with screw terminals 0,6 Nm Stripping length with screw terminals 8 mm Dimensions Height 87 mm Width 45 mm Depth 121 mm Weight 345 g Where standards are undated, the 2020-07 latest editions shall apply. Operating Manual PNOZ X13 | 18 20187-EN-07...
  • Page 19: Safety Characteristic Data

    If the service life graphs are not accessible, the stated PFH value can be used irrespective of the switch frequency and the load, as the PFH value already considers the relay's B10d value as well as the failure rates of the other components. Operating Manual PNOZ X13 | 19 20187-EN-07...
  • Page 20: Service Life Graph

    European Parliament and of the Council. The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/support/downloads. Representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ost- fildern, Germany Operating Manual PNOZ X13...
  • Page 21 We are represented internationally. Please refer to our homepage www.pilz.com for further details or contact our headquarters. Headquarters: Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com, Internet: www.pilz.com...

Table of Contents