ELECTRICAL CONNECTION

Once you have removed the covers of the control
panel boxes both on the Master and on the
Slave motors (pict 26), insert the SLAVE control
panel onto the MASTER control panel inside the
MASTER operator (Fig. 30 - 31) inserting the
spacer support in the appropriate hole (Fig. 30).
Carry out the electrical connection as shown in
Fig. 69 in order to check 'dead man's switch'
control to up-and-over door commands.
WARNING: IPX4 can only be guaranteed by
mounting the rubber cable fairleads in the
electrical switchboard into the relative container
holes (Fig. 27) and the rounded slotted wire seal
on the cover latch (Fig. 28).
LIMIT SWITCHES ADJUSTMENT - MASTER OPERATOR
- Position DIP 8 to ON and press the command button on the electrical switchboard (Fig.
31) to start up-and-over door movement. Release the button once the operation has
been carried out. Slacken the holding screw for the green cam and turn until activating the
microswitch (Fig. 34).
- Tighten the green cam holding screw (Fig. 35).
- Press the key on the electronic switchboard (Fig. 31) to close the up-and-over door
movement. Release the button once the closing operation has been completed. Slacken
the holding screw for the red cam and turn until the microswitch is activated (Fig. 37).
- Tighten the red cam holding screw (Fig. 38).
- Carry out a complete opening and closing cycle to check that the cams are positioned
perfectly. Correct positions if required.
- Turn DIP8 to OFF.
Refer to the section ELECTRICAL CONNECTIONS for connection to auxiliary units and
switchboard functions.
Close the electrical box with the appropriate cover using the 6 screws provided.
SLAVE
CARD
code ACQ9087
26
ELECTRICAL CABLE FIXING SIDE
MASTER OPERATOR
The electrical cable that powers the operator
should NOT be fixed to the telescopic lever (Fig.
29).
The cable should be curved in order that it is not
subject to twist, tension or tearing while the door
is in movement.
Cables exiting the door plate hole should be
protected with some form of sheath to avoid their
being cut during movement.
28
30
38
DIP 8
27
29
SLAVE
CARD
code
ACQ9087
31