9. Troubleshooting
Alarm Message
Failure description
ILeak-PRO
Leakage current protection
01/02/03/04
Relay check fail
RelayChk-FAIL
DCinj-FAULT
High DC injection current
Reverse_DC
wrong DC polarity
One of the DC string is
Reve-DC
reversely connected
Screen OFF
Inverter internally damaged
with DC applied
Table 9.1 Fault message and description
NOTE:
If the inverter displays any alarm message as listed in Table 9.1; please
turn off the inverter (refer to Section 5.2 to stop your inverter) and wait for 15
minutes before restarting it (refer to Section 5.1 to start your inverter). If the
failure persists, please contact your local distributor or the service center.
Please keep ready with you the following information before contacting us.
1. Serial number of Solis Three Phase Inverter;
2. The distributor/dealer of Solis Three Phase Inverter (if available);
3. Installation date.
4. The description of problem (i.e. the alarm message displayed on the LCD and the status
of the LED status indicator lights. Other readings obtained from the Information submenu
(refer to Section 6.2) will also be helpful.);
5. The PV array configuration (e.g. number of panels, capacity of
, etc.);
6. Your contact details.
.40.
Solution
1. Check AC and DC connection.
2. Check inverter inside cable connection.
1. Restart inverter or contact installer.
1. Disconnect the AC first, then the DC switch,
and wait for five minutes, Unplug the reverse
connected string, Confirm the safety,
Re-make DC terminal, After confirming the
correct polarity, connect to the inverter.
1. Please check the inverters' PV string polarity,
if there are strings reversely connected wait for
the night when the solar irradiance is low and the
PV string current down below 0.5A. Turn off the
two DC switchs and fix the polarity issue.
1.Do not turn off the DC switches as it will
damage the inverter.
2.Please wait for the solar irradiance reduces
and confirm the string current is less than
0.5A with a clip-on ammeter and then turn
off the DC switches.
3.Please note that any damages due to wrong
operations are not covered in the device
warranty.
panels, number of strings

10. Specifications

Model
Max. DC input voltage (Volts)
Rated DC voltage (Volts)
Start-up voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
Max short circuit input current (Amps)
MPPT number/Max input strings number
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
Rated grid voltage (Volts)
Rated grid output current (Amps)
Max. output current (Amps)
Power Factor (at rated output power)
THDi (at rated output power)
Rated grid frequency (Hertz)
Max.efficiency
EU efficiency
Dimensions (W*H*D)
Weight
Topology
Self consumption (night)
Operating ambient temperature range
Relative humidity
Ingress protection
Cooling concept
Max.operation altitude
Grid connection standard
Safty/EMC standard
DC connection
AC connection
Display
Communication connections
Warranty
CSI-15K-T220GL02-E
1100
600
180
200...1000
3*26
3*40
3/6
15000
15000
15000
3/PE, 220
39.4
43.3
0.8leading~0.8lagging
<3%
50/60
98.8%
98.3%
647*629*252mm
45kg
Transformerless
<1W
-25℃...+60℃
0~100%
IP65
Natural convection
4000m
En50549, G99, AS4777.2-2015, VDE0126-1-1,
IEC62727, VDE4105-2018, NB/T 32004, IEEE1547
IEC62109-1/-2, EN61000-6-2,
EN61000-6-3, UL1741
MC4 connector
OT Terminal (max 185 mm²)
LCD, 2×20 Z
RS485, Optional: Wifi, GPRS , PLC
5 years (extand to 20 years)