SUN2000-(196KTL-H0, 200KTL-H2, 215KTL-H0)
User Manual
Figure 7-13 Power adjustment parameters (special user)
----End
Parameters
No.
Parameter
1
Remote power
schedule
2
Schedule instruction
valid duration (s)
3
Maximum active
power (kW)
4
OFF at 0% power
limit
Issue 02 (2020-10-30)
Description
If this parameter is set to Enable,
the inverter responds to the
scheduling instruction from the
remote port. If this parameter is
set to Disable, the inverter does
not respond to the scheduling
instruction from the remote port.
Specifies the time for maintaining
the scheduling instruction.
Specifies the output upper
threshold for the maximum active
power to adapt to different market
requirements.
If this parameter is set to Enable,
the inverter shuts down after
receiving the 0% power limit
command. If this parameter is set
to Disable, the inverter does not
shut down after receiving the 0%
power limit command.
Copyright © Huawei Technologies Co., Ltd.
7 Man-Machine Interactions
Remarks
-
When this parameter is set
to 0, the scheduling
instruction takes effect
permanently.
-
-