Move to the second char position (segment in the middle) and swipe-up or down until char "d"
appears
-
Move on the third char position (segment on the right) and swipe-up or down until char "F" appears
-
Enter the par. value by touching the PRG icon for 3 sec.
NOTE: pay attention to the upper or lower case when browsing through the available characters.
For simplicity, here is the complete list of available characters: A, b, C, d, E, F, G, H, i, L, M, n, o, P, q, r, S, t,
u, V, Y, 0, 1, 2, 3, 4, 5, 6, 7, 8 and 9.

4.11 PARAMETER MENU

When in Programmin Menu, it is possible to enter the Parameter Menu touching the PRG icon for 3 sec.
The Prog Level 1 icon will indicate the first level of the programming menu (group labels).
The Browsing icon will indicate that there are other groups of parameters.
When in PROG LEVEL 1, it is possible to browse through the available groups of parameters by using the H-
swipe gesture. The circular construction of this menu permits to move left or right through the groups.
Here are the available groups:
Group Label
Description
rEG
Main regulation parameters
Prb
Probe configuration parameters
diS
Visualization parameters
dEF
Defrost configuration parameters
FAn
Evaporator and condenser fan configuration parameters
AUS
Auxiliary regulator parameters
ALr
Alarm configuration parameters
oUt
Digital and analogue output configuration parameters
inP
Digital input configuration parameters
ES
Energy saving configuration parameters
Cnt
Counters, read only values
rtC
Real Time Clock configuration parameters
E2
Memory storage management