ADVANCED SETTINGS

Advanced settings should only be adjusted by a competent person, the wrong configuration can have
a detrimental effect on the thermostat and the heating system.
Description
Optimised start
Boiler starts heating in advance of schedule so heating reaches the
required temperature at the time specified.
Optimised stop
Boiler stops heating in advance of schedule so heating reaches the
required temperature at the time specified.
Delayed start
If the room temperature is close to target temperature the heating
start time is delayed to save energy.
Display tolerance
Select the display tolerance of the room temperature, this can be set
at increments of 0.5° or 0.1°C.
Temperature offset
Fine tune the room temperature display -2.5° to 2.5°C.
Daylight saving time
Automatically move to daylight saving.
Frost protection
The temperature that will be used to protect your home when the
thermostat is off. Can be set 5°C.
Service phone number
Opportunity to input Installer contact number for service reminders.
Factory setting
OFF
OFF
OFF
0.1°C
0
ON
5
C
0