Download Print this page

Advertisement

Quick Links

4601503-P1V-A Issue 1
Disconnect air and electrical supplies before
attempting repair or maintenance.
See ISO 4414-1982 for safety requirements covering
the installation and use of pneumatic equipment.
Koppla ifrån luft och elektriska anslutningar innan
reparations-och underhållsarbeten påbörjas.
Se ISO 4414-1982 för säkerhetsbestämmelser
täckande installation och användning av pneumatisk
utrustning.
1. Important Notes
Safety- and Warning Signs
The safety and warning instructions contained
should invariably be followed!
IMMEDIATE DANGER
Possible consequences: Death or grave injuries.
DANGEROUS SITUATION
Possible consequences: slight or minor injuries.
DAMAGING DANGER
Possible consequences: damage to drive or the
surrounding area.
Important instructions relating to explosion
protection.
Application tips and other useful information.
NOTICE ALL DOCUMENTATIONS !
Before beginning work this operating instruction
booklet has to be read through carefully. Always follow
the instructions during operation. Give this operating
instruction booklet to the operator.
Definition
Potentially explosive atmosphere (hereinafter referred to as
"Ex-area")
= An atmosphere which could become explosive due to
local and operational conditions.
The observance of the operating instructions is the
precondition for an error free operation and the fulfillment
of warranty claims. Therefore, please read the operating
instruction booklet prior to working with the air motor! The
operating instruction booklet contains important tips for
motor service and should therefore be kept in the vicinity
of the motor.
Disposal
Always observe the most current regulations for
disposal.
Especially during installation, repair or maintenance water
damaging agents, such as:
• lubricating greases and oil
• hydraulic fluid
• cooling agents
• solvent-containing cleaning agents may not leak into
the ground or into the sewage system!
Such materials must be stored, transported, contained
and recycled in suitable containers.
Housing parts, tooth rings, shafts, as well as gear parts
should be disposed off as steel scrap.

Advertisement

loading
Need help?

Need help?

Do you have a question about the P1V-A160B Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Parker P1V-A160B Series

  • Page 1 4601503-P1V-A Issue 1 Disconnect air and electrical supplies before NOTICE ALL DOCUMENTATIONS ! attempting repair or maintenance. Before beginning work this operating instruction See ISO 4414-1982 for safety requirements covering booklet has to be read through carefully. Always follow the installation and use of pneumatic equipment. the instructions during operation.
  • Page 2 This air motor is mainly used to generate a rotating maintenance and repair work may only be performed by motion in industrial equipment. Parker or qualified persons / technical experts and if the Basically, the air motor is approved for the use in the food following items are observed: industry.
  • Page 3 130°C; there is a safety margin of 5°C. (130°C) This is the maximum permissible surface temperature of the motor if used in an explosive atmosphere containing dust. „Observe special requirements“ In the Operating Instruction Booklet marked with the symbol www.parker.com/euro_pneumatic...
  • Page 4 To avoid a swelling of the seal rings and damage to Grounding internal parts of the air motor, use only solvents approved by Parker (such as HAKU 1025-810-1 cold cleaner). Seal The air motor must be grounded, for example by using material: NBR/FKM •...
  • Page 5 – to less than 0.5 bar (7.25 PSI). Install a maintenance unit, fill it with oil and adjust oiler as needed. Fill the oil container of the oiler to the indicated oil level. Lubricants Use only lubricants approved by the manufacturer. www.parker.com/euro_pneumatic...
  • Page 6 Is the ambient temperature in accordance temperature may not increase more than 40K. with requirements? Ambient temperature in the Ex-area: -20°C to +40°C If the surface temperature exceeds the mandate, the motor must be stopped immediately. Please immediately contact Parker! www.parker.com/euro_pneumatic...
  • Page 7 If Non-Parker parts are installed, then Parker is justified to Regularly check the oil-level in the oiler and refill oiler as avoid any existing warranty and liability obligations.
  • Page 8 •••••• Rest of the air motor order code For continuous lubrication-free operation. For more information about our maintenance services, (To obtain the longest possible service life, we recommend no please contact your local parker sales office. oil in the air.) www.parker.com/euro_pneumatic...
  • Page 9 • Disconnect the air motor from the equipment it is attached to. Parker Pneumatic guarantees that its products are safe, and as a supplier of pneumatic equipment we ensure that the equipment is • Remove the silencer package (if one is installed).
  • Page 10 Air supply is Optimise • • located too far installation from the motor Insufficient Provide the required • • • lubrication air quality Worn vanes or Exchange vanes • • • • vanes are jammed www.parker.com/euro_pneumatic...
  • Page 11 www.parker.com/euro_pneumatic...
  • Page 12 (from AT, BE, CH, CZ, DE, DK, EE, ES, FI, parker.southafrica@parker.com parker.hungary@parker.com FR, IE, IL, IS, IT, LU, MT, NL, NO, PL, PT, RU, SE, SK, UK, ZA) © 2016 Parker Hannifin Corporation. All rights reserved. 4601503-P1V-A May 2017 Parker Hannifin Ltd. Tachbrook Park Drive Tachbrook Park,...