Summary of Contents for WAGO 750-613/040-000

  • Page 1 Manual WAGO I/O SYSTEM 750 XTR 750-613/040-000 System Power Supply 24 VDC XTR System Power Supply; 24 VDC; Extreme Version 1.3.0...
  • Page 2 We wish to point out that the software and hardware terms as well as the trademarks of companies used and/or mentioned in the present manual are generally protected by trademark or patent. WAGO is a registered trademark of WAGO Verwaltungsgesellschaft mbH. Manual Version 1.3.0...
  • Page 3: Table Of Contents

    WAGO I/O SYSTEM 750 XTR Table of Contents 750-613/040-000 System Power Supply 24 VDC XTR Table of Contents Notes about this Documentation .............. 5 Validity of this Documentation ..............5 Copyright....................5 Symbols ....................6 Number Notation ..................7 Font Conventions ..................7 Important Notes ..................
  • Page 4 Table of Contents WAGO I/O SYSTEM 750 XTR 750-613/040-000 System Power Supply 24 VDC XTR Use in Hazardous Environments ............38 Marking Configuration Examples ............39 6.1.1 Marking for Europe According to ATEX and IECEx ......39 6.1.2 Marking for the United States of America (NEC) and Canada (CEC) ....................
  • Page 5: Notes About This Documentation

    (System Power Supply 24 VDC XTR). The I/O module 750-613/040-000 shall only be installed and operated according to the instructions in this manual, in the system description for the WAGO I/O SYSTEM 750 XTR and in the manual for the used fieldbus coupler/controller.
  • Page 6: Symbols

    Notes about this Documentation WAGO I/O SYSTEM 750 XTR 750-613/040-000 System Power Supply 24 VDC XTR Symbols Personal Injury! Indicates a high-risk, imminently hazardous situation which, if not avoided, will result in death or serious injury. Personal Injury Caused by Electric Current! Indicates a high-risk, imminently hazardous situation which, if not avoided, will result in death or serious injury.
  • Page 7: Number Notation

    WAGO I/O SYSTEM 750 XTR Notes about this Documentation 750-613/040-000 System Power Supply 24 VDC XTR Additional Information: Refers to additional information which is not an integral part of this documentation (e.g., the Internet). Number Notation Table 1: Number Notation...
  • Page 8: Important Notes

    2.1.1 Subject to Changes WAGO Kontakttechnik GmbH & Co. KG reserves the right to provide for any alterations or modifications. WAGO Kontakttechnik GmbH & Co. KG owns all rights arising from the granting of patents or from the legal protection of utility patents.
  • Page 9: Technical Condition Of Specified Devices

    These modules contain no parts that can be serviced or repaired by the user. The following actions will result in the exclusion of liability on the part of WAGO Kontakttechnik GmbH & Co. KG: •...
  • Page 10: 2.1.4.1.2 Packaging

    Important Notes WAGO I/O SYSTEM 750 XTR 750-613/040-000 System Power Supply 24 VDC XTR • Observe national and local regulations for the disposal of electrical and electronic equipment. • Clear any data stored on the electrical and electronic equipment. •...
  • Page 11: Safety Advice (Precautions)

    Always adhere to the EMC directives applicable to your application. Power from SELV/PELV power supply only! All field signals and field supplies connected to this XTR I/O module (750-613/040-000) must be powered from SELV/PELV power supply(s)! Manual Version 1.3.0...
  • Page 12 Important Notes WAGO I/O SYSTEM 750 XTR 750-613/040-000 System Power Supply 24 VDC XTR Do not touch hot surfaces! The surface of the housing can become hot during operation. If the device was operated at high ambient temperatures, allow it to cool off before touching it.
  • Page 13 WAGO I/O SYSTEM 750 XTR Important Notes 750-613/040-000 System Power Supply 24 VDC XTR Avoid electrostatic discharge! The devices are equipped with electronic components that may be destroyed by electrostatic discharge when touched. Please observe the safety precautions against electrostatic discharge per DIN EN 61340-5-1/-3. When handling the devices, please ensure that environmental factors (personnel, work space and packaging) are properly grounded.
  • Page 14: Device Description

    WAGO I/O SYSTEM 750 XTR 750-613/040-000 System Power Supply 24 VDC XTR Device Description The I/O module 750-613/040-000 (System Power Supply 24 VDC XTR) provides the internal system power to the downstream modules and increases the system current supply by 2 A.
  • Page 15 Operation in shipbuilding or offshore and onshore applications The supplementary power supply regulations (see section “Connect Devices” > “Power supply concept”) must be observed for the certified operation of the supply module 750-613/040-000 in shipbuilding or offshore and onshore applications! Mixed operation Mixed operation (standard/XTR modules) within a node is possible when groups of modules are electrically isolated on the field side (i.e., electrically isolated...
  • Page 16: View

    Device Description WAGO I/O SYSTEM 750 XTR 750-613/040-000 System Power Supply 24 VDC XTR View Figure 1: View Table 3: Legend for Figure “View” Pos. Description Details See Section Marking possibility with Mini- Status LEDs “Device Description” > “Display Elements”...
  • Page 17: Connectors

    WAGO I/O SYSTEM 750 XTR Device Description 750-613/040-000 System Power Supply 24 VDC XTR Connectors 3.2.1 Data Contacts/Local Bus Communication between the fieldbus coupler/controller and the I/O modules as well as the system supply of the I/O modules is carried out via the local bus. The contacting for the local bus consists of 6 data contacts, which are available as self-cleaning gold spring contacts.
  • Page 18: Power Jumper Contacts/Field Supply

    750-613/040-000 System Power Supply 24 VDC XTR 3.2.2 Power Jumper Contacts/Field Supply The power supply module 750-613/040-000 has 2 self-cleaning power jumper contacts that transmit power for the field side. The contacts on the right side of the power supply module are designed as spring contacts.
  • Page 19: Cage Clamp

    WAGO I/O SYSTEM 750 XTR Device Description 750-613/040-000 System Power Supply 24 VDC XTR 3.2.3 CAGE CLAMP ® Connectors Figure 3: CAGE CLAMP ® Connectors Table 5: Legend for Figure “CAGE CLAMP ® Connectors” Designation Connector Function 24 V System supply voltage: 24 VDC...
  • Page 20: Display Elements

    Status of No 24 V field supply voltage on the power operating jumper contacts. voltage 24 V field supply voltage on the power jumper Green contacts. field supply Operating Elements The I/O module 750-613/040-000 has no operating elements. Manual Version 1.3.0...
  • Page 21: Schematic Diagram

    WAGO I/O SYSTEM 750 XTR Device Description 750-613/040-000 System Power Supply 24 VDC XTR Schematic Diagram Figure 5: Schematic Diagram Manual Version 1.3.0...
  • Page 22: Technical Data

    Device Description WAGO I/O SYSTEM 750 XTR 750-613/040-000 System Power Supply 24 VDC XTR Technical Data 3.6.1 Device Data Table 7: Technical Data – Device Width 12 mm Height (from upper edge of DIN-rail) 60.6 mm Depth 100 mm Weight 58.5 g...
  • Page 23: Connection Type

    WAGO I/O SYSTEM 750 XTR Device Description 750-613/040-000 System Power Supply 24 VDC XTR 3.6.3 Connection Type Table 9: Technical Data – Field Wiring Wire connection CAGE CLAMP ® Cross section 0.25 mm² … 2.5 mm² / AWG 24 … 14 Stripped lengths 8 mm …...
  • Page 24: Approvals

    Approvals More information about approvals. Detailed references to the approvals are listed in the document “Overview Approvals WAGO I/O SYSTEM 750”, which you can find via the internet under: www.wago.com  DOWNLOADS  Documentation  System Description. The following approvals have been granted to 750-613/040-000 I/O modules:...
  • Page 25: Standards And Guidelines

    WAGO I/O SYSTEM 750 XTR Device Description 750-613/040-000 System Power Supply 24 VDC XTR Standards and Guidelines 750-613/040-000 I/O modules meet the following standards and guidelines: Table 14: Standards and Rated Conditions for Explosion Protection Applications ATEX acc. Directive 2014/34/EU General Requirements...
  • Page 26: Table 15: Climatic And Mechanical Environmental Conditions And

    Device Description WAGO I/O SYSTEM 750 XTR 750-613/040-000 System Power Supply 24 VDC XTR Table 15: Climatic and Mechanical Environmental Conditions and Shipbuilding Standard Test Value Transport EN 60870-2-2 Ct2(2k4) (except precipitation/water/moisture) Mechanical Environmental Conditions EN 61850-3 Achieved EN 60870-2-2...
  • Page 27: Table 16: Emc - Immunity To Interference

    WAGO I/O SYSTEM 750 XTR Device Description 750-613/040-000 System Power Supply 24 VDC XTR The I/O module 750-613/040-000 meets the following EMC standards as these standards relate to the I/O module: Table 16: EMC – Immunity to Interference Standard Test Value Electrostatic Discharge •...
  • Page 28 Device Description WAGO I/O SYSTEM 750 XTR 750-613/040-000 System Power Supply 24 VDC XTR Table 16: EMC – Immunity to Interference Standard Test Value Alternating Components of the Voltage to DC Line Connections • EN 61000-4-17 15 % • EN 60255-26 Damped Oscillatory Waves •...
  • Page 29: Table 17: Emc - Emission Of Interference

    WAGO I/O SYSTEM 750 XTR Device Description 750-613/040-000 System Power Supply 24 VDC XTR Table 17: EMC – Emission of Interference Standard Test Value Enclosure Emission of Interference • EN 61000-6-3 30 dB(µV/m), QP, 30 MHz … 230 MHz • EN 55032 Class B 37 dB(µV/m), QP, 230 MHz …...
  • Page 30: Table 18: Standards And Rated Conditions For Rail Applications (En 50155)

    EN 50121-3-2 5.5 EMC (Emission of Interference, EN 50121-3-2 Immunity to Interference) EN 50121-4 EN 50121-5 9.11 Materials (Fire Protection) EN 45545-2 Hazard level HL3 WAGO is a company certified in accordance with the IRIS quality standard. Manual Version 1.3.0...
  • Page 31: Mounting

    750-613/040-000 System Power Supply 24 VDC XTR Mounting Mounting Sequence Fieldbus couplers, controllers and I/O modules of the WAGO I/O SYSTEM 750 are snapped directly on a carrier rail in accordance with the European standard EN 60175 (DIN 35). The reliable positioning and connection is made using a tongue and groove system.
  • Page 32: Inserting And Removing Devices

    Mounting WAGO I/O SYSTEM 750 XTR 750-613/040-000 System Power Supply 24 VDC XTR Inserting and Removing Devices Do not touch hot surfaces! The surface of the housing can become hot during operation. If the device was operated at high ambient temperatures, allow it to cool off before touching it.
  • Page 33: Removing The I/O Module

    WAGO I/O SYSTEM 750 XTR Mounting 750-613/040-000 System Power Supply 24 VDC XTR Press the I/O module into the assembly until the I/O module snaps into the carrier rail. Figure 7: Snap the I/O Module into Place (Example) With the I/O module snapped in place, the electrical connections for the data contacts and power jumper contacts (if any) to the fieldbus coupler/controller or to the previous or possibly subsequent I/O module are established.
  • Page 34: Connect Devices

    Do not connect more than one conductor at one single connection! If more than one conductor must be routed to one connection, these must be connected in an up-circuit wiring assembly, for example using WAGO feed- through terminals. To open the CAGE CLAMP insert the actuating tool into the opening ®...
  • Page 35: Power Supply Concept

    WAGO I/O SYSTEM 750 XTR Connect Devices 750-613/040-000 System Power Supply 24 VDC XTR Power Supply Concept The system power supply and field power supply must be powered via SELV/PELV power supply units. The system power supply is fed in via the upper 24 V/0 V CAGE CLAMP ®...
  • Page 36: Supplementary Power Supply Regulations

    24 VDC field side power supply and used to filter the 24 VDC field power supply, is required for the certified operation of the system power supply 750-613/040-000 in shipbuilding or offshore and onshore applications.
  • Page 37: Power Supply Units

    Connect Devices 750-613/040-000 System Power Supply 24 VDC XTR 5.2.2 Power Supply Units The WAGO I/O SYSTEM 750 XTR requires 24 VDC voltage (system supply) for operation. Recommendation A stable power supply cannot always be assumed everywhere. Therefore, you should use regulated power supplies to ensure the quality of the supply voltage (see also table “WAGO power supply units”).
  • Page 38: Use In Hazardous Environments

    WAGO I/O SYSTEM 750 XTR 750-613/040-000 System Power Supply 24 VDC XTR Use in Hazardous Environments The WAGO I/O SYSTEM 750 (electrical equipment) is designed for use in Zone 2 hazardous areas and shall be used in accordance with the marking and installation regulations.
  • Page 39: Marking Configuration Examples

    WAGO I/O SYSTEM 750 XTR Use in Hazardous Environments 750-613/040-000 System Power Supply 24 VDC XTR Marking Configuration Examples 6.1.1 Marking for Europe According to ATEX and IECEx Figure 12: Marking Example According to ATEX and IECEx Figure 13: Text Detail – Marking Example According to ATEX and IECEx Manual Version 1.3.0...
  • Page 40: Table 19: Description Of Marking Example According To Atex And Iecex

    Use in Hazardous Environments WAGO I/O SYSTEM 750 XTR 750-613/040-000 System Power Supply 24 VDC XTR Table 19: Description of Marking Example According to ATEX and IECEx Marking Description TUEV 07 ATEX 554086 X Approving authority resp. certificate numbers IECEx TUN 09.0001 X...
  • Page 41: Figure 14: Marking Example For Approved Ex I I/O Module According To

    WAGO I/O SYSTEM 750 XTR Use in Hazardous Environments 750-613/040-000 System Power Supply 24 VDC XTR Figure 14: Marking Example for Approved Ex i I/O Module According to ATEX and IECEx Figure 15: Text Detail – Marking Example for Approved Ex i I/O Module According to ATEX and...
  • Page 42: Table 20: Description Of Marking Example For Approved Ex I I/O Module According To Atex And Iecex

    Use in Hazardous Environments WAGO I/O SYSTEM 750 XTR 750-613/040-000 System Power Supply 24 VDC XTR Table 20: Description of Marking Example for Approved Ex i I/O Module According to ATEX and IECEx Marking Description TUEV 12 ATEX 106032 X Approving authority resp.
  • Page 43: Marking For The United States Of America (Nec) And Canada (Cec)

    WAGO I/O SYSTEM 750 XTR Use in Hazardous Environments 750-613/040-000 System Power Supply 24 VDC XTR 6.1.2 Marking for the United States of America (NEC) and Canada (CEC) Figure 16: Marking Example According to NEC Figure 17: Text Detail – Marking Example According to NEC 500...
  • Page 44: Figure 18: Text Detail - Marking Example For Approved Ex I I/O Module

    Use in Hazardous Environments WAGO I/O SYSTEM 750 XTR 750-613/040-000 System Power Supply 24 VDC XTR Figure 18: Text Detail – Marking Example for Approved Ex i I/O Module According to NEC 505 Table 22: Description of Marking Example for Approved Ex i I/O Module According to NEC 505...
  • Page 45: Figure 20: Text Detail - Marking Example For Approved Ex I I/O Modules

    WAGO I/O SYSTEM 750 XTR Use in Hazardous Environments 750-613/040-000 System Power Supply 24 VDC XTR Figure 20: Text Detail – Marking Example for Approved Ex i I/O Modules According to CEC 18 attachment J Table 24: Description of Marking Example for Approved Ex i I/O Modules According to CEC 18...
  • Page 46: Installation Regulations

    Use in Hazardous Environments WAGO I/O SYSTEM 750 XTR 750-613/040-000 System Power Supply 24 VDC XTR Installation Regulations For the installation and operation of electrical equipment in hazardous areas, the valid national and international rules and regulations which are applicable at the installation location must be carefully followed.
  • Page 47 WAGO I/O SYSTEM 750 XTR Use in Hazardous Environments 750-613/040-000 System Power Supply 24 VDC XTR Explosive atmosphere occurring simultaneously with assembly, installation or repair work must be ruled out. Among other things, these include the following activities • Insertion and removal of components •...
  • Page 48: Special Notes Regarding Ansi/Isa Ex

    Use in Hazardous Environments WAGO I/O SYSTEM 750 XTR 750-613/040-000 System Power Supply 24 VDC XTR 6.2.2 Special Notes Regarding ANSI/ISA Ex For ANSI/ISA Ex acc. to UL File E198726, the following additional requirements apply: • Use in Class I, Division 2, Group A, B, C, D or non-hazardous areas only •...
  • Page 49: List Of Figures

    WAGO I/O SYSTEM 750 XTR List of Figures 750-613/040-000 System Power Supply 24 VDC XTR List of Figures Figure 1: View ...................... 16 Figure 2: Data Contacts ..................17 Figure 3: CAGE CLAMP Connectors ..............19 ® Figure 4: Display Elements .................. 20 Figure 5: Schematic Diagram ................
  • Page 50: List Of Tables

    List of Tables WAGO I/O SYSTEM 750 XTR 750-613/040-000 System Power Supply 24 VDC XTR List of Tables Table 1: Number Notation ..................7 Table 2: Font Conventions ..................7 Table 3: Legend for Figure “View” ............... 16 Table 4: Legend for Figure “Power Jumper Contacts” ......... 18 Table 5: Legend for Figure “CAGE CLAMP...
  • Page 51 WAGO I/O SYSTEM 750 XTR 750-613/040-000 System Power Supply 24 VDC XTR Manual Version 1.3.0...
  • Page 52 WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 • D - 32385 Minden Hansastraße 27 • D - 32423 Minden Phone: +49 571 887 – 0 Fax: +49 571 887 – 844169 E-Mail: info@wago.com Internet: www.wago.com...