Summary of Contents for Pentair Hydromatic Water SP50
Page 1
Pump Installation and Service Manual SP50/SP50AB Now Includes SP50AB Submersible Sewage Ejector Pump Information NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system.
2. Risk of Electrical Shock: NOTE: Some city regulations General Connect only to a properly do not allow installing a Information grounded receptacle. pump with plastic pipe. Check local regulations. Septic tank is to be vented in accordance with local Thank you for purchasing your plumbing codes.
CAUTION: sure signs of water, stator can Pump unplug cord before continuing be checked with the ohmmeter Servicing reassembly pump to see if it can be reused. is functional. 4. Ground check. Set ohmmeter Read the following instructions 3. Checking motor stator. If scale pointer to R X 100K carefully before replacing any motor does not run when tested...
Page 5
check, if the needle goes to 6. Replacing seal. If water is 8. Reassembly of stator and zero motor found in motor, seal must housing. Replace stator (20) probability has a wire touching be replaced. Remove bottom with terminal block turned the stator shell at some point casting (5).
Page 6
11.Manual pumps. All general Pump instructions automatic Servicing pumps apply to manual pumps except the level switch is not used and the power cord does Pump is now ready for check not have a vent tube. run before air testing and Manual models have the plug filling with oil.
SP50 Parts List SP50A x SP50M x Single Phase SP50M x Three Phase Ref. No. Part No. Description Qty. Ref. No. Part No. Description Qty. 11584-043-4 Nameplate 11584-043-4 Nameplate 14981-001-1 Plug - Pipe 1/4" 14981-001-1 Plug - Pipe 1/4" 56-036-2 Motor Housing (Includes Handle) 56-023-2 Motor Housing (Includes Handle)
Page 8
SP50AB1 Parts List SP50AB1 Ref. No. Part No. Description Qty. 11584-043-4 Nameplate 14981-001-1 Plug - Pipe 1/4" 56-013-2 Motor Housing (Includes Handle) 13349-000-1 Motor- 115 V. single phase 77-003-1 O - Ring Sq. cut 239-005-1 Bolt 208-010-2 Flange - Discharge 324-001-1 Gasket - Discharge Flange 202-010-2...
Page 12
WARRANTY Hydromatics Pump warrants to the original purchaser of each Hydromatic Pump product(s) that any part thereof that proves to be defective in material or workmanship within one year from date of installation or 18 months from manufacture date, whichever comes first, will be replaced at no charge with a new or remanufactured part, F.O.B.