KKT KOLBE TRITON User Manual page 38

Table of Contents

Advertisement

Available languages

Available languages

Mounting the hood
• Now open the front flap, remove the
metal grease filter and mark the dril-
ling positions through the screw holes.
Note: Some models do not have drill
holes. Here you can fix the hood at any
position.
+ 2x
• Remove the hood from the wall and
drill the marked holding holes
(ø 8 mm) for the internal screws.
• Hang up the hood again and fix it with
all screws.
• Now place the chimney on the hood.
Pull out the inner shaft part to the
desired height and mark the position
of the upper edge for both shaft parts
on the wall.
Then remove the shaft again.
38
• Place the shaft mounting brackets on
the appropriate markings and fasten
them to the wall either by marking
and pre-drilling the screw holes or by
tightening the screws evenly if the wall
is suitable.
?
• Attach the exhaust hose to the air
outlet of the hood body.
• Now clip the chimney onto the wall
brackets from top to bottom.
The upper part can be fixed with two
small screws.
• The exhaust air hose is led through the
shaft and connected to the exhaust air
opening if necessary.