O
UTPUT SPECIFICATION
Static Regulation
Line Regulation Voltage
Line Regulating Current
Load Regulation Voltage
Load Regulation Current
Dynamic Response Time
@Load Step 10 - 90%
Output Voltage [V]
HP/E 5KW Unit [A]
HP/E 10KW Unit [A]
HP/E 15KW Unit [A]
Voltage ripple (p-p)
20MHz
Voltage ripple (p-p)
300KHz
5
)
mV
Voltage ripple (rms
20MHz
5
)
mV
Voltage ripple (rms
300KHz
Current ripple (p-p)
Current ripple (rms)
Primary / Sekundary
DC - Output/ Earth
Primary / Earth
13
Rise time full Load
13
Rise time no Load
13
Fall time full Load
Fall time no Load
7
Rel. Accuracy ±[%]
Voltage [V] 0,25
Current [A] 0,4
Relative Accuracy for Sens operation (worst case) [%]
Voltage [V] 0,5
Max. Sens Voltage over
7
nominal Voltage
Max. Sens Voltage inside the
7
normal Voltage range
Resolution Voltage
Display
Voltage setting resolution
Resolution Current
Display
Current setting resolution
OVP
OCP
OTP
UI-Modus
ET System electronic GmbH
:
15
20
25
35
40
x
250 200 150
125
x
500
x
350
250
x
750
x
x
375
Other combinations of Voltage and Current also possible, ask the Manufakturer
Basic calculation of possible combinations are:
Pout = Vout x Iout / Pmax for one Unit 90KW / Cmax = 250A each 5KW
12
12
12
12
12
40
80
80
80
140
12
12
12
12
12
15
35
35
35
60
15
35
35
35
60
12
12
12
12
12
10
25
25
25
40
6 ms
6 ms
6 ms
6ms
12 ms
5 ms
5 ms
5 ms
5 ms
10 ms
15 ms 15 ms 15 ms 15 ms 20 ms
0,038 0,050 0,063 0,088
0,100
1,000 1,000 0,800 0,580
0,500
0,075 0,100 0,125 0,175
0,200
5% of F.S. (if higher voltage is needed ask manufacturer)
15V - 99,99V
00.00
0A - 9,999A
0.000
Over Voltage Protection: is adjustable between 0% and 120% of Voltage full range
Over Current Protection: is realised by the current set point.
The output current can not go over the set value
Over Temperature Protection: if the internal heat sink tempearatury is go above 90°C
the divice will automaticaly shut down
Voltage and Current operation mode: Voltage and current are setable
± 0,1% of F.S.
± 0,02% F.S.
± 0,02% F.S.
± 0,05 % F.S. ± 2mV
± 0,05% F.S. ± 20mA
< 3ms
45
70
80
100
120
75
65
50
250
175
130
100
x
x
195
150
12
12
12
12
140
140
140
140
900
12
12
12
12
60
60
60
60
400
60
60
60
60
12
12
12
12
40
40
40
40
300
<0,5 % of F.S.
<0,4 % of F.S.
3.000VAC
500VDC
2.150VDC
12 ms
12 ms
20 ms
20 ms
20 ms
10 ms
10 ms
10 ms
10 ms
10 ms
20 ms
20 ms
20 ms
20 ms
40 ms
5 s unter 50VDC
0,113
0,175
0,200
0,250
0,480
0,288
0,260
0,200
0,225
0,350
0,400
0,500
±1% of F.S.
10A - 99,99A
00.00
Technical Specifications
150
300
600
800
35
17
8,5
6,5
75
40
17
13
100
50
25
19
12
12
12
12
900
900
1000
12
12
12
12
400
400
700
400
400
400
400
12
12
12
12
300
300
300
2.000VDC
20 ms
20 ms
40 ms
40 ms 40 ms 6 ms
10 ms
10 ms
10 ms
20 ms 20 ms 5 ms
40 ms
50 ms
60 ms
80 ms 100 ms 25 ms
0,375
0,750
1,500
2,000
0,140
0,068
0,034
0,026
0,750
1,500
3,000
4,000
100V - 999,9V
000.0
100A - 999,9A
000.0
1000 1200 1500
5
4,2
3,3
10
8
6,6
15
12
9,9
1200 2500 2500
800 1500 1500
400
400
500
300
300
400
2,500
3,000 3,750
0,020
0,017 0,013
5,000
6,000 7,500
1.000V - 1.500V
0000
1.000A - 9.999A
0000
3