Out of specification
S600
Impermissible electron-
ics temperature
S601
Overfilling
S603
Impermissible operating
voltage
Maintenance
M500
Error in the delivery sta-
tus
M501
Error in the delivery sta-
tus
M504
Error at a device inter-
face
M505
No echo available
M507
Error in the transmitter
settings
M508
Data error in program
memory Bluetooth con-
troller
M509
Software update
SITRANS LR110
Operating Instructions, 01/2020, A5E49829006
Code
Text message
Temperature of the
electronics in the non-
specified range
Danger of vessel over-
filling
Terminal voltage too
small
Code
Text message
Hardware defect
Transmitter does not
detect an echo during
operation
Antenna dirty or defec-
tive
Error during setup
Error when carrying out
a reset
Auto false each suppres-
sion faulty
11.4 Status messages according to NE 107
Cause
Rectification
Check ambient temper-
ature
Insulate electronics
Make sure that there is
no further filling
Check level in the vessel
Check terminal voltage,
increase operating volt-
age
Cause
Rectification
Check connections
Exchanging the elec-
tronics
Send transmitter for re-
pair
Clean the antenna
Use a more suitable an-
tenna/transmitter
Remove possible false
echoes
Optimize transmitter
position and orientation
Carry out reset and re-
peat setup
Diagnostics and troubleshooting
DevSpec
State in CMD 48
Byte 23, Bit 4 of
Byte 14 ... 24
Byte 23, Bit 5 of
Byte 14 ... 24
Byte 23, Bit 6 of
Byte 14 ... 24
DevSpec
State in CMD 48
Bit 0 of Byte 14 ... 24
Bit 1 of Byte 14 ... 24
Bit 4 of Byte 14 ... 24
Bit 5 of Byte 14 ... 24
Bit 7 of Byte 14 ... 24
Bit 8 of Byte 14 ... 24
Bit 9 of Byte 14 ... 24
37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sitrans lr110

Table of Contents