Operation
1.
Spray test pattern. Adjust pressure to
eliminate heavy edges.
2.
Use smaller tip size if pressure
adjustment cannot eliminate heavy
edges.
3.
Hold gun perpendicular, 10-12 in. (25-30
cm) from surface. Spray back and forth;
overlap by 50%.
4.
Trigger gun after moving. Release
trigger before stopping. For additional
spraying information, see separate gun
manual.
16

Clear Spray Tip Clog

To avoid injury, never point gun at your
hand or into a rag!
1.
Release trigger. Engage trigger lock.
Rotate Spray Tip. Disengage trigger
lock. Trigger gun at waste area to clear
clog.
2.
Engage trigger lock. Return Spray Tip to
original position. Disengage trigger lock
and continue spraying.