Page 1
Gas and Air Sensors Installation Manual aSENSE RL Dismounting of the sensor 1 top part 2 lid 3 front part 4 wall plate 5 screw 6 label with settings inside the top part Pull the top part upwards Push the front part with the lid upwards...
Page 2
Air of different temperature may otherwise disturb the temperature measurements. The top part is pushed under the Terminals and jumpers on aSENSE RL. locking hooks of the wall plate The darker positions are default settings. and is secured with a screw Terminals and jumpers are located under the top part.
Page 3
(halfwave rectifier). A single transformer may be used for the entire system. Note 2: aSENSE RL can deliver a voltage or a current loop for Out(1) / Out(2). To change between voltage and current output mode the hardware jumpers are used. There is one jumper for Out(1) and one for Out(2), so that one output can be a voltage output and the other a current output.
Page 4
7,5 mm (0,295 inches) and screw head height less than 2,5 mm (0,1 inches) Dimensions of mounting plate in mm and (inches) ® SenseAir AB (headquarter) Stationsgatan 12 Phone: +46-(0)653 - 71 77 70 Box 96 E-mail: info@senseair.com...
Need help?
Do you have a question about the aSENSE RL and is the answer not in the manual?
Questions and answers